3.6 Information on optical radiation
Due to the withdrawal of the LED from IEC 60825, the assessment of eye safety is done
according to CIE S009/E:2002
“Photo Biological Safety of Lamps and Lamp Systems”.
Within the risk assessment system of CIE S009/E:2002 (DIN EN 62471) the LEDs used in the
Corona II illumination unit are depending on the LED color, the focus and the intensity might
be in this risk classes:
LED
Dark Field
A
B
C
D
White
Up to Class 2
„Medium risk “
Up to Class 2
„Medium risk “
Up to Class 1
„Low risk “
Up to Class 1
„Low risk “
Red, Green
Up to Class 1
„Low risk “
Up to Class 1
„Low risk “
Up to Class 1
„Low risk “
Up to Class 1
„Low risk “
Blue, IR
(850 nm / 940 nm)
Up to Class 2
„Medium risk “
Up to Class 2
„Medium risk “
Up to Class 2
„Medium risk “
Up to Class 2
„Medium risk “
UV
(365 and 395 nm)
Up to Class 3
„High risk “
Up to Class 3
„High risk “
Up to Class 3
„High risk “
Up to Class 3
„High risk “
LED
Bright Field (H)
White, Red, Green
Up to Class 1 „Low risk “
Blue, IR
(850 nm and 940 nm)
Up to Class 2
„Medium risk “
UV (365 and 395 nm)
Not available
LED
Tube Light (T+U)
White, Red, Green
Up to Class 1 „Low risk “
Blue, IR
(850 nm and 940 nm)
Up to Class 2
„Medium risk “
UV (365 and 395 nm)
Not available
It is assumed that these devices for Class 1 do not normally present a hazard.