Chromasens CD40127_R02 allPIXA_pro_User Manual.docx
17
Sensor alignment:
Position:
X: < +/- 100 µm
Y: < +/- 100 µm
Z: < +/- 100 µm
Rotation about:
Y: < +/- 0.1 °
Z: < +/- 0.1 °
Planarity of sensor surface:
< +/- 0.50 µm
Sensor window:
Thickness:
0.7 mm
Refraction index
1.5
Optical path extension:
0.24 mm
Sensor alignment is an important issue for:
Adjusting multi-camera systems
Replacing cameras
Mechanical design of the mounting system for the camera
2.6 Adapter and accessories
2.6.1 Lenses adapters and mounts
Chromasens offers a large variety of accessories which are designed to provide maximum
flexibility and get most out of the camera.
You can find the complete list of all accessories including descriptions and detailed drawings
in our login area of our website at
NOTE
For more information about accessories, refer to the corresponding
accessories catalogue or the configuration sheet at our website
www.chromasens.de/en/color-line-scan-camera-allpixa-pro
First pixel
X
Y
Z