5
RENEWAL PARTS IDENTIFICATION
Wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333-557518-001
End Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 039-510848-001
Vinyl Grip. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 024-304894-001
Grill for STAR-06. . . . . . . . . . . . . . . . . . . . . . . 143-304892-001
Grills for STAR-14 (2) . . . . . . . . . . . . . . . . . . . 134-304892-003
Hardware for Mounting Grills GR14TW
Screw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248-075512-123
Square Nut . . . . . . . . . . . . . . . . . . . . . . . . . 200-048688-007
IMPORTANT INSTRUCTIONS
GENERAL
IMPORTANT: SAVE THESE INSTRUCTIONS
FIRE HAZARD.
Do not use as a residential or
household heater. Keep combustible material away
from heater. Do not operate heater where flamma-
ble vapors, gases or liquids are present.
To avoid personal injury read “IMPORTANT
INSTRUCTIONS” on this page before installation or
operation of heater.
When using electrical appliances, basic precautions should
always be followed to reduce risk of fire, electric shock and injury
to persons, including the following:
1.
Read all instructions before using this heater.
2.
This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials, such as
furniture and papers at least 7 feet from the front of the heater.
3. Do not leave heater unattended while in operation.
4.
Always disconnect heater when not in use.
5.
Do not use outdoors in areas subject to wind.
6.
Connect to properly grounded outlets or building ground.
7.
This heater has hot surfaces. Do not use it in areas where gaso-
line, paint or flammable liquids are used or stored.
8.
Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electric
shock or injury to persons.
9.
In order to prevent equipment damage, protect with a ground
fault device such as Chromalox STAR-TG series monitor.
10. These instructions amend the fixed instructions that came
with the original heater.
SAVE THESE INSTRUCTIONS
WIRING
Amperage
Cord Ga./No. cond.
Model
Volts
KW
1 Phase
3 Phase
1 Phase
3 Phase
STAR-05-81-P
208
4.5
21.6
NA
12/3
NA
STAR-05-21-P
240
4.5
18.8
NA
12/3
NA
STAR-05-71-P
277
4.5
16.2
NA
14/3
NA
STAR-05-41-P
480
4.5
9.4
NA
14/3
NA
STAR-05-61-P
600
4.5
7.5
NA
14/3
NA
STAR-06-83-P
208
6
28.8
16.7
10/3
12/4
STAR-06-23-P
240
6
25.0
14.4
10/3
12/4
STAR-06-71-P
277
6
21.7
—
10/3
—
STAR-06-43-P
480
6
12.5
7.2
12/3
12/4
STAR-06-63-P
600
6
10.0
5.8
12/3
12/4
STAR-14-83-P
208
13.5
NR
37.5
NR
6/4
STAR-14-23-P
240
13.5
NR
32.5
NR
8/4
STAR-14-71-P
277
13.2
47.7
—
6/3
—
STAR-14-43-P
480
13.5
28.1
16.2
10/3
12/4
STAR-14-63-P
600
13.5
22.5
13.0
10/3
12/4
Table 1
NA - Not Available
NR - Not Recommended
Use type “SO” or equal power cord. Refer to table 1 for proper wire gage and number of conductors.