background image

5

RENEWAL PARTS IDENTIFICATION

Wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333-557518-001
End Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 039-510848-001
Vinyl Grip. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 024-304894-001
Grill for STAR-06. . . . . . . . . . . . . . . . . . . . . . . 143-304892-001

Grills for STAR-14 (2) . . . . . . . . . . . . . . . . . . . 134-304892-003

Hardware for Mounting Grills GR14TW

Screw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248-075512-123
Square Nut . . . . . . . . . . . . . . . . . . . . . . . . . 200-048688-007

IMPORTANT INSTRUCTIONS

GENERAL

IMPORTANT: SAVE THESE INSTRUCTIONS

FIRE HAZARD.

Do not use as a residential or

household heater. Keep combustible material away
from heater. Do not operate heater where flamma-
ble vapors, gases or liquids are present.

To avoid personal injury read “IMPORTANT
INSTRUCTIONS” on this page before installation or
operation of heater.

When using electrical appliances, basic precautions should

always be followed to reduce risk of fire, electric shock and injury
to persons, including the following: 

1.

Read all instructions before using this heater.

2.

This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials, such as
furniture and papers at least 7 feet from the front of the heater.

3. Do not leave heater unattended while in operation.
4.

Always disconnect heater when not in use.

5.

Do not use outdoors in areas subject to wind.

6.

Connect to properly grounded outlets or building ground.

7.

This heater has hot surfaces. Do not use it in areas where gaso-
line, paint or flammable liquids are used or stored. 

8.

Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electric
shock or injury to persons.

9.

In order to prevent equipment damage, protect with a ground
fault device such as Chromalox STAR-TG series monitor.

10. These instructions amend the fixed instructions that came

with the original heater.

SAVE THESE INSTRUCTIONS

WIRING

Amperage

Cord Ga./No. cond.

Model

Volts

KW

1 Phase

3 Phase

1 Phase

3 Phase

STAR-05-81-P

208

4.5

21.6

NA

12/3

NA

STAR-05-21-P

240

4.5

18.8

NA

12/3

NA

STAR-05-71-P

277

4.5

16.2

NA

14/3

NA

STAR-05-41-P

480

4.5

9.4

NA

14/3

NA

STAR-05-61-P

600

4.5

7.5

NA

14/3

NA

STAR-06-83-P

208

6

28.8

16.7

10/3

12/4

STAR-06-23-P

240

6

25.0

14.4

10/3

12/4

STAR-06-71-P

277

6

21.7

10/3

STAR-06-43-P

480

6

12.5

7.2

12/3

12/4

STAR-06-63-P

600

6

10.0

5.8

12/3

12/4

STAR-14-83-P

208

13.5

NR

37.5

NR

6/4

STAR-14-23-P

240

13.5

NR

32.5

NR

8/4

STAR-14-71-P

277

13.2

47.7

6/3

STAR-14-43-P

480

13.5

28.1

16.2

10/3

12/4

STAR-14-63-P

600

13.5

22.5

13.0

10/3

12/4

Table 1

NA - Not Available
NR - Not Recommended

Use type “SO” or equal power cord. Refer to table 1 for proper wire gage and number of conductors.