WARNING: 

Hazard of Electric Shock. Disconnect all

power before installing heater.

WARNING:

Hazard of Electric Shock. Any installation

involving electric heaters must be effectively ground-
ed in accordance with the National Electrical Code.

WARNING:

This heater is not intended for use in haz-

ardous atmospheres where flammable vapors, gases,
liquids or other combustible atmospheres are present

as defined in the National Electrical Code. Failure to
comply can result in explosion or fire.

1.

Check that the electrical service is the same on the nameplate.

2.

Determine desired mounting location per instructions on
nameplate.

3.

Remove connection box cover.

4.

Bring in correct fused electrical service to appropriate knock-

out. Suitable for 75˚C field wiring.

Chromalox

®

DIVISION  

4

                                      SECTION  

CPHH

SALES

REFERENCE

DATE

SERVICE REFERENCE

PF477-2

161-562516-001

MARCH, 1999

(Supersedes PF477-1)

Installation, Operation

and

MAINTENANCE

© 2010 Chromalox, Inc.

Type CPHH — Pumphouse Utility Heater

INSTALLATION

Specifications

Model

Volts

Watts

Amps

BTUH

Length

Weight

Stock

PCN

(In.)

(Lbs.)

CPHH-50011

120

500

4.2

1707

17-3/8

5.0

S

350190

CPHH-50031

208

375

1.8

1280

17-3/8

5.0

S

350203

CPHH-50031

240

500

2.1

1707

17-3/8

5.0

S

350203

WIRING

Electric wiring to heater must be installed in accordance with the

National Electrical Code and with local codes by a  qualified person.

WARNING: 

Use copper conductors only.

1.

Wire per appropriate wiring diagram below, connecting
ground wire to green ground screw.

2.

On 120V units, the thermostats must be in the hot line.

3.

Fasten heater to wall using four wood screws or screw
anchors.

4.

Replace connection box cover.

Wiring Diagrams —

L1

N

Stat

Black

White

120V     1Ø     60 Hz

L1

L2

Stat

Black

Black

240V     1Ø     60 Hz

17-3/8
16-7/8

1/4" Dia. (4 pts.)

1-1/2

3-13/16

5-1/2

2

2-1/4

7/8" Dia. K.O.