Chromalox NWH-185015 Скачать руководство пользователя страница 3

RENEWAL PARTS IDENTIFICATION

Note:

When ordering parts for Model Numbers suffixed by “XX” or any other letter or letters not specifi-

cally identified on this instruction sheet, order Renewal Parts on special order basis, giving name of
part, part number, model number and description.

Replacement

Element

Model

Volts Phase

kW

Assembly

NWH-185015

240

3 50

155-013185-046

NWH-185015

480

3 50

155-013185-047

NWH-187515

240

3 75

155-013185-049

NWH-187515

480

3 75

155-013185-050

NWH-1810015

240

3 100

155-013185-052

NWH-1810015

480

3 100

155-013185-053

NWH-1812515

240

3 125

155-013185-058

NWH-1812515

480

3 125

155-013185-059

NWH-1815015

240

3 150

155-013185-061

NWH-1815015

480

3 150

155-013185-062

NWH-1817515

240

3 175

155-013185-064

NWH-1817515

480

3 175

155-013185-065

NWH-1820015

240

3 200

155-013185-067

NWH-1820015

480

3 200

155-013185-068

Parts Common To All Heaters

Flexitallic Gasket  . . . . . . . . . . . . . . . . . . . . . . . . . . .132-019779-007

Standard Gasket  . . . . . . . . . . . . . . . . . . . . . . . . . . .132-017222-007

MAINTENANCE

1.

WARNING:

Hazard of Shock. Disconnect 

all power before servicing heater.

2.

Remove heating element assembly periodically to check
heater sheath for scaling, corrosion or excessive oxidation.
Correct operating conditions to minimize sheath deterioration.

3.

Periodically check temperature control and limit control oper-
ation to insure accurate and safe process operation.

4.

Check all electrical connections periodically and retighten
connections which may have loosened in service. Replace
wire and wire terminals which show signs of oxidation which
would interfere with establishment of reliable electrical con-
nections.

Содержание NWH-185015

Страница 1: ...ndards The 18 copper sheathed tubular elements are centered in a 8 diameter galvanized steel heating chamber and welded to a removable galvanized steel flange The assembly is surrounded by 3 insulation and sheet metal jacket Depending upon the order specifications the NWH 18 may or may not be factory equipped with an AR or other Chromalox thermostat Such thermostats function to control outlet temp...

Страница 2: ...t be installed in accordance with local and National Electrical Codesby a qualified person as defined in the NEC 3 Power controllers must be used when heaters are rated for 480 volt service or if the amperage rating of the heaters exceeds the contact rating of the thermostat 4 Refer to Wiring Diagram Table B for the proper wiring dia gram for connecting heater WIRING Note Dotted lines indicate cus...

Страница 3: ...5 013185 062 NWH 1817515 240 3 175 155 013185 064 NWH 1817515 480 3 175 155 013185 065 NWH 1820015 240 3 200 155 013185 067 NWH 1820015 480 3 200 155 013185 068 Parts Common To All Heaters Flexitallic Gasket 132 019779 007 Standard Gasket 132 017222 007 MAINTENANCE 1 WARNING Hazard of Shock Disconnect all power before servicing heater 2 Remove heating element assembly periodically to check heater ...

Страница 4: ...UT 84404 Phone 1 800 368 2493 www chromalox com TA U0 EF Litho in U S A Limited Warranty Please refer to the Chromalox limited warranty applicable to this product at http www chromalox com customer service policies termsofsale aspx ...