2
MOS Series Hot Oil System
Installation Instructions
General Information
The Chromalox Heat Transfer Unit is a thoroughly engi-
neered, pretested package, designed to give years of
service, virtually maintenance free if properly installed.
The MOS series can operate at 600˚F (315˚C) or 650˚F
(343˚C) at atmospheric pressure (depending upon heat
transfer fluid properties and unit configuration) with
features that comply with the National Electrical Code.
Common to all models: electronic process controller,
air-cooled mechanical seal, chamber insulation, dis-
charge pressure gauge, steel heater sheath, cast iron,
centrifugal pump; power requirements 240 to 600 volts,
3 phase, 60 cycles, 50 thru 500kW.
In hazardous areas, pipe surfaces could
achieve temperatures high enough to cause
auto-ignition of the hazardous material pres-
ent. Consult Article 500 of the National Elec-
tric Code for further information on the maxi-
mum allowable temperature for a specific
application.
Unit Proportions
Unit Size
Dry
Weight
(Lbs.)
Width
(In.)
Depth
(In.)
Height
1
(In.)
Flow
Rate
2
GPM
Pressure
2
TDH
(Ft.)
Motor
HP
Inlet/Outlet
Connection
ANSI
System
Capacity
(Gal.)
50 & 75 kW
900
36
42
96
80
130
5
2”, 150#
24
100-150 kW
1400
36
42
96
120
130
7.5
3”, 150#
35
175-300 kW
2600
48
54
96
200
130
10
3”, 150#
65
350-500 kW
3500
48
54
96
200
3
130
10
3
3”, 150#
3
85
1
650˚F Option will add 8” to overall height.
2
Refer to pump graph for full operating range
3
Option for 300 GPM 20HP pump with 4”, 150# inlet/outlet
H
D
W
MOS 50-150 kW Unit (Front View)
MOS 175-500 kW Unit (Rear View)
H
D
W