
41
EC Declaration of Conformity
We,
Chromalox Precision Heat and Control
1347 Heil Quaker Boulevard
LaVergne, Tennessee 37086-3536
Phone: +1 (615) 793-7561
Fax: +1 (615) 213-8091
declare under sole responsibility that the following described product in our delivered version complies with
the appropriate basic safety and health requirements of the EC Low Voltage Directive (2006/95/EC) and EC
Electromagnetic Compatibility Directive (2004/108/EC) based on its design and type, as brought into circula-
tion by us. In case of alteration of the machine, not agreed upon by us, this declaration will lose its validity.
Description of the Electrical Equipment: MaxPac SCR controllers
Model Number: MaxPac Series; MaxPac I, II, III
Applicable Harmonized Standards:
Low Voltage Directive
EMC Directive
Specification: EN60947-4-3:2000
1. Radiated Disturbance Emissions – 30 to 1000
Low-voltage switch gear and
MHz Electric Field
control gear
EN 61000-6-4:2001 / EN 55011:2007
Part 4-3: Contactors and
2. Conducted Disturbance Emissions – Voltage
motor-starters
EN 61000-6-4:2001 / EN 55011:2007
AC semiconductor controllers
and contactors for non-motor loads
3. Conducted Disturbance Immunity
Utilization
AC-51 Non-inductive or slightly
EN 61000-6-2:2005 / EN 61000-4-6:1996
Category:
inductive loads, resistive
furnaces
4. Radiated Disturbance Immunity
EN 61000-6-2:2005 / EN 61000-4-3:1995
Pollution
Normally only non-conductive
Degree 2
pollution occurs. Occasionally,
5. Electrical Fast Transients/Bursts Immunity
a temporary conductivity
EN 61000-6-2:2005 / EN 61000-4-2:1995
caused by condensation may
be expected.
6. Voltage Dips and Interrupts Immunity
EN 61000-6-2:2005 / EN 61000-4-11:1994
Voltage Rating: 400 VAC 50 Hz Line
230 VAC 50 Hz Instrument max
7. Electrostatic Discharge Immunity
75 watts
EN 61000-6-2:2005 / EN 61000-4-2:1995
Impulse Rating: 2.5 KV for 5 seconds
8. Voltage Fluctuations/Flicker
EN 61000-3-3 / A2:2005
Overload
140% for 1 second
Current Profile:
9. Harmonic Current Emissions
EN 61000-3-2:2006
Fuses:
500 Volt, 200KA RMS
symmetrical interrupting rating,
I
2
t fusing provided with all CE
units.
Содержание MaxPac
Страница 1: ...PK480 5 0037 75428 June 2018 User s Manual MaxPac...
Страница 2: ......
Страница 28: ...26 5 Controller Configuration...
Страница 29: ...27...