Start-Up

For up to 30 amp loads, use minimum 10 AWG 

wiring or better for 120/277 VAC power input.

Connecting power to the unit.

1.  Powering up with 120/277 VAC: To power up the 

unit apply 120/277 VAC to the terminal block ac-

cording to the schematic below:

Connections for Power, Cable and Earth Ground  

 

AC Power, Earth & Heating Cable 

Terminal Blocks 

N or L2 – IN 

(AC Low) 

Cable OUT 

Cable OUT 

L or L1 – IN 

(AC High) 

Protective

Ground

 

2.  Programming with 9VDC battery:

  The DTS-HAZ may be programmed with a 9VDC 

battery should standard service line voltage be un-

available.

 

Note: Powering unit with 9VDC should only be used 

for programming purposes and not operation of the 

unit.

Programming of the 9 VDC battery shall not be 

done in hazardous locations.

3.  Programming and alarm overview

  Digital Thermostat must have the following compo-

nents set to correctly control the temperature:

  a.  Setpoint – targeted temperature value that con-

troller will aim to reach

  b. Hi Temperature Alarm – Temperature at which 

the unit goes into high temperature alarm mode.

  c. Lo Temperature Alarm – Temperature at which 

the unit goes into low temperature alarm mode.

  d.  Deadband – The allowable temperature differen-

tial between the Set Point and the Sensed Tem-

perature during normal operation. The Deadband 

is centered on the Setpoint. The Deadband has a 

range of 2 to 10 deg. in 2 degree increments.

  

 

  The Load is removed once the temperature is 1/2 

way between the Setpoint and the upper limit of 

the Deadband.

  e.  Temperature Units – selection between degrees 

Fahrenheit or Celsius.

  f.  Soft Start Function – The soft start may be en-

abled or disabled. When enabled, the Soft start 

algorithm initiates at power on & whenever low 

end of dead band is realized. When initiated, 0% 

- 100% Power is achieved over 167 seconds.

  g.  Alarm State – The FACTORY DEFAULT SETTING 

IS NORMALLY CLOSED. You may toggle this 

setting to Normally Open via the control push 

buttons.

Connecting RTD Wire

1. Connect RTD wire according to the schematic:

+

-

White

Red

COM

Red

3 Wire RTD

RTD     

Com
RTD

-

RTD

+

Alarm Wiring

The alarm on the DTS unit is a non-arcing, solid state 

relay. In order for it to properly function, it must be sup-

plied with either AC or DC voltage, depending on which 

model is selected. The alarm on the DTS-HAZ func-

tions only with AC voltage. The alarm on the DTS-HAZ-

DC functions only with DC voltage.

DTS-HAZ

Load

AC

12-277 VAC

Customer Supplied

DTS Alarm Wiring Options

DTS-HAZ-DC

Load

DC

0-42 VDC

Customer Supplied

+

-

+

=

Содержание DTS-HAZ

Страница 1: ...1 Installation Instructions DTS HAZ DTS HAZ DC for use with Self Regulating Constant Wattage Mineral Insulated Electric Heating Cables PJ944 12 161 562581 049 April 2020 ...

Страница 2: ...2 ...

Страница 3: ...on Box 7 1 RTV 2 1 Line Ambient Sensing RTD 8 1 O Ring 3 1 Compression Fitting 9 1 Self Regulating Cable Grommet 4 1 Locknut 10 1 Constant Wattage Cable Grommet 5 1 Silicone Termination Boot 11 1 9 VDC Battery Connector 6 1 Pipe Standoff 12 1 Protective Sleeve 7 11 4 5 6 12 8 3 1 2 10 9 ...

Страница 4: ...nstallation The instal lation and proximity for the disconnect device must satisfy the electrical Authority having ju risdiction for the installation Branch circuit protection should be set for 40 amps or lower In all cases where the symbol is used on the product consult the documentation to find out the nature of the potential hazard and any ac tions to be taken General The DTS HAZ and DTS HAZ DC...

Страница 5: ...e adapter Chromalox model SPA not included is required 4 While bending the heating ca ble work the cable through the braid opening Pull the braid tight 2 Score the outer insulation 7 inches from the end of the cable Lightly cut the outer jacket up the center to the end of heating cable and remove the outer jack et from the cable WARNING DO NOT CUT METAL BRAID Note If using over braid only cable sk...

Страница 6: ... shall have the included protective sleeve slid over it once inside the enclosure Then insert grounding braid into grounding terminal Attach junction box cover to seal enclosure Access hole on right is designed for a 3 4 conduit hub Note The conduit hub shall be listed for Class 1 Div 2 Class II Div 1 2 Class III Div 1 2 and NEMA 4X rated by a nationally recognized testing laboratory For ATEX or I...

Страница 7: ...opri ate screw driver ONLY until snug It is recom mended that the lid be secured with a torque of 12 15 inch lbs per screw Overtightening or uneven tightening may cause the lid to break which would void all environmental and haz ardous location approvals Due to an electrical shock hazard do not operate thermostat if lid is cracked broken or uneven with enclosure Be sure to install this device vert...

Страница 8: ... mode d Deadband The allowable temperature differen tial between the Set Point and the Sensed Tem perature during normal operation The Deadband is centered on the Setpoint The Deadband has a range of 2 to 10 deg in 2 degree increments The Load is removed once the temperature is 1 2 way between the Setpoint and the upper limit of the Deadband e Temperature Units selection between degrees Fahrenheit...

Страница 9: ...DOWN MODE UP DOWN MODE UP DOWN MODE UP DOWN MODE UP DOWN SSrt UnIt bAnd LotP HItp StpT Troubleshooting Alarm Type Display Solution Sensor Open Sens err Check if your sensor is correctly connected to the unit Sensor Shorted Sens err Check if your sensor is correctly connected to the unit Lo Temperature Blinking between sensed temperature and LotP Sensed temperature is below Lo Temp Threshold Alarm ...

Страница 10: ...urface a minimum of 3 inches or 76 mm must be maintained from the rear of the DTS HAZ to the mounting surface This is neces sary to provide adequate airflow across the heat sink at the rear of the DTS 3 When installing the DTS on a vertical surface the Pipe Standoff is not used and is typically replaced by rigid 1 NPT conduit The conduit shall terminate into the Compression Fitting Ordering Inform...

Страница 11: ... a 0 125 Amp 350 VAC 2AG fuse Maximum RTD output 1 25 volts 7 milliamps Temperature Rating UL T4a IEC ATEX T4 Protection IP66 Settings Setpoint 80 F to 1100 F 62 C to 593 C Alarms High temp to 1150 F 621 C Low temp to 80 F 62 C Deadband 2 F or C to 100 F or C 1 to 50 around the setpoint Alarm Function Mode Default Optional Normal Operation Closed Open Alarm Condition Open Closed Power Off Open Ope...

Страница 12: ...e Chromalox limited warranty applicable to this product at http www chromalox com customer service policies termsofsale aspx 2016 Chromalox Inc All rights reserved Chromalox 103 Gamma Drive Pittsburgh PA 15238 412 967 3800 www chromalox com ...

Отзывы: