Technician settings (Cont’)
Pg. 14
Use DIP switch S2 to short the
- “ON” - Short measuring times – for test/commissioning only (measuring times will be divided by 60).
- “OFF” - Normal operation.
Short measuring times: A real 1 hour will take 1 minute and a real 1 minute will take 1 second.
Short measuring times (test only) - DIP switch S2
DIP switches S3 and S4 – Not in use (must be in OFF position)
S3 OFF, S4 OFF
Restore default values
Move DIP switch S1 to ON position.
Press and hold the [ON] button for 10 seconds. The controller will beep.
Move DIP switch S1 back to OFF position.
In order to save changes and return to normal display, move DIP switch S1 back to
OFF position.
Save changes and return to normal display
Important: Changes made to technician parameters will not take effect as
long as DIP switch S1 is in ON position.
Chroma-FP-OD Series
Owner’s manual & Technician Settings
1-800-443-2640
www.chromalox.com