GENERAL DATA (40 to 300A Models)
Power Supply
24Vdc ±10%, Clas II, max 8VA
Max 10VA with CFW-OP terminal - isolation 1000V
Fan power supply
24Vdc ±10%, 500mA @ 25Vdc
Signals
Eight leds:
RN (Green) run state of CPU
ER (Red) error signal
DI1, DI2, (Yellow) state of digital inputs INDIG1, INDIG2
O1,O2,O3 (Yellow) state of power control
BT (Yellow) state key HB
Protection
IP20
Work/storage temperature
0...+50°C (refer to dissipation curves) / -20...+85°C
Relative humidity
20…85% RH non-condensing
Ambient conditions for use
indoor use, altitude up to 2000m
Installation
panel with screws
Installation requirements
Installation category II, pollution level 2, double isolation Max. temperature of
air surrounding device 40°C for temperature >40°C refer at derating curves -
Device type: “UL Open Type”