1.3 Product Inspection
Read the following preliminary instructions before in-
stalling and using the CFW modular power controller.
This will make start-up faster and avoid some prob-
lems that could be mistakenly interpreted as malfunc-
tions or limitations of the controller.
Immediately after unpacking the unit, check the order
code and the other data on the label attached to the
outside of the container.
Write them on the following table.
This data must always be available and given to Chro-
malox Customer Care representatives if technical ser-
vice is needed.
SN ........................................................(Serial Number)
CODE ...................................................(Product code)
TYPE. .........................................................(Order code)
SUPPLY ..................... (Type of electrical power supply)
VERS ............................................... (Firmware Version)
Check that the controller is in perfect condition, was
not damaged during shipment, and that the package
also contains the CD that contains other useful infor-
mation such as the “Configuration and Programming”
manual, memory map etc...
Immediately report any errors, shortages, or signs of
damage to your Chromalox dealer.
Check that the order code matches the configuration
requested for the intended application by consulting
the section: “Technical-Commercial Information.”
See paragraph “ Dimensions and mounting” before in-
stalling the CFW on the machine/host system control
panel.
To configure with a PC, use the Chromalox C-PWR
software and relative connection cable.
For the order code, see Section “Technical-Commer-
cial Information”.
Users and/or system integrators who want detailed
information on serial communication between Chro-
malox standard and/or industrial PCs and Chromalox
Programmable Instruments can access Technical
Reference Documents on serial communication and
MODBus protocol, etc., in Adobe Acrobat format on
the Chromalox website www.chromalox.com:
• Serial Communication
• MODBus Protocol
• FIELDBUS protocols (Various)
Before calling Chromalox Customer Care in case of as-
sumed malfunctions, please see the Troubleshooting
Guide in the “Maintenance” section and, if necessary,
the F.A.Q. (Frequently Asked Questions) section on the
Chromalox website www.chromalox.com
Diagnostic Alarm Options
0
Absent
1
Partial or total load failure alarm.
(HB) + diagnostic alarms
CFW
-3
-150
48
-0 1
1
R
1 -1 -EP
Model
Three-phasee Model (3 PH)
Nominal current (150 A)
Nominal voltage (480 V)
PID Opt. Temperature(Absent)
Auxiliaries Inputs (4 TC/linear input (60mV)
Contol option (Current limit)
Auxiliary Output opz. (4 Relays)
Diagnostics Alarms Options (HB) + diagnostic alarms)
Fuses (Self-contained)
FIELDBUS Port 2 opz. (Ethernet IP )