3 Phase Voltages*

Output

Quantity and Rating

No./kW

Elec

at

of Contactors

of

Rating Cap.

Vol.

212˚F

Heating

Model

(BHP) (kW) (Gals.) (Lbs./Hr.) 208

240

480† Elements

Type CES — 0-100 PSIG

CES-6

.6

6

6

18

30

30

30

1-6

CES-9

.9

9

6

27

30

30

30

1-9

CES-12

1.22

12

6

36.2

40

30

30

1-12

CES-18

1.73

17

6

51.2

50

50

30

1-17

CES-24

2.45

24

14.3

72.3

2-40

2-30

2-30

2-12

1-40

1-40

1-12

CES-30

2.95

29

14.3

87.4

1-50

1-30

40

1-17

CES-36

3.47

34

14.3

102.5

2-50

2-50

50

2-17

1-40

1-30

1-40

1-12

CES-48

4.69

46

14.3

138.7

2-50

2-50

1-30

2-17

2-50

2-30

2-12

CES-60

5.91

58

14.3

174.8

2-40

2-50

2-40

2-17

CES-72

6.93

68

14.3

205

4-50

4-50

2-50

4-17

CES-100

10.40

102

27.8

307

6-50

6-50

3-50

6-17

CES-135

13.9

136

30.5

410

8-50

4-50

8-17

1-30

CES-160

16.1 157.5

30.5

475

7-60

3-60

7-22.5

CES-180

18.4

180

30.5

543

8-60

4-60

8-22.5

Chromalox

®

DIVISION  

4

                                      SECTION  

CES

SALES

REFERENCE

DATE

SERVICE REFERENCE

Installation, Operation

and

RENEWAL PARTS IDENTIFICATION

PQ444-1

MAY, 1999

(Supersedes PQ444)

161-562789-002

© 2010 Chromalox, Inc.

Type CES-6 through CES-180 Electric Steam Boiler

Standard Trim is 100 PSI — 0-90 Operating Pressure Range

Boiler Serial Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Power Circuit Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Control Circuit Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

National Board No.   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Amps  . . . . . . . . . . . . . . . Phase  . . . . . . . . . . . Cy  . . . . . . . . . .

Important —

This data file contains the National Board Registration Certificate for your boiler. It must be kept near the boiler at all times.

* Single phase available up to and including 24 kW capacity.
† All boilers must have separate 120V Control Circuit or Transformer.
Boilers under 40 amps max are not fused.

Содержание CES-100

Страница 1: ...3 50 6 17 CES 135 13 9 136 30 5 410 8 50 4 50 8 17 1 30 CES 160 16 1 157 5 30 5 475 7 60 3 60 7 22 5 CES 180 18 4 180 30 5 543 8 60 4 60 8 22 5 Chromalox DIVISION 4 SECTION CES SALES REFERENCE DATE SE...

Страница 2: ...nection Conduit Box Element I Steam Outlet Sight Glass Element Access Door 5 8 7 16 Bolt Hole typical Drain Blowdown Valve K A B C Check Valve D H F E G Operating Pressure Control Safety Valve Outlet...

Страница 3: ...ust be main tained 3 Complete all piping to boiler Connect water line to tagged fitting on the motor and pump assembly if used or to tagged fitting on water control feeder 4 When any type of feed othe...

Страница 4: ...ed 6 WARNING Substitution of components or modifica tion of wiring system voids the warranty and may lead to dangerous operating conditions 7 SPECIAL INSTRUCTIONS FOR CUSTOMERS SUPPLY ING THEIR OWN CO...

Страница 5: ...R C2 FU4 FU5 FU6 2L1 2L3 2L2 Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 3 2PS BR Heater Contactor Feed Water Boiler On 3 GND B FU6 B 1PB Off 1 GND 1 HTR C...

Страница 6: ...3 C2 FU7 FU8 FU9 C3 3L1 1L3 3L2 3 HTR C3 Heater Contactor Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 5 2PS BR Heater Contactors Feed Water Boiler On 3 GND...

Страница 7: ...C3 C4 FU 10 11 12 4 Htr FU10 FU11 FU12 C4 4L1 4L3 4L2 4 HTR C4 Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 7 2PS BR Heater Contactor Feed Water Boiler On...

Страница 8: ...ND Cabinet Exterior Left Side Cabinet Exterior Right Side Panel Layout Feed Water Electrical Connection Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 9 FU 1...

Страница 9: ...H1 H4 H2 H3 FU24 FU23 FU22 FU21 FU20 FU13 C8 C7 7 HTR 6 HTR 7L1 8L3 8L2 8L1 5L3 7L2 C5 C7 Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 11 FU 1 2 3 FU 4 5 6...

Страница 10: ...7L2 FU FU FU C7 C6 Heater Contactor Heater Contactor Heater Contactor Heater Contactor Heater Contactor Wire Color Code B Black BR Brown R Red O Orange Y Yellow G Green BL Blue W White Diagram 13 FU...

Страница 11: ...in valve or release man ual blowdown switch If low water cutout is automatic reset pump or solenoid will return water level to normal If low water cutout is manual reset then manual reset button on Mc...

Страница 12: ...ustomer Supplied 2 Turn on boiler and allow pressure to build up to operating pressure 3 Only open globe valve at quarter turns at first introducing smaller amounts of steam into process Avoid opening...

Страница 13: ...E CLOSED and the BOILER ON should light up again Now turn the wheel on the large timer until the OFF tab passes the TIME NOW arrow The BOILER ON light should go out and the valve should begin to open...

Страница 14: ...circuit balance is achieved The slightest change in the pressure of the controlled medium will cause a change in the number of elements energized to compensate for it thus keeping the pressure constan...

Страница 15: ...stage loads of the type used in Chromalox steam boilers It features progressive sequencing first on first off which equalizes the operating time of each load This control gives visual indication of e...

Страница 16: ...ed 3 Connect piping from discharge to water inlet check valve on boil er with minimum of 90 bends or other restrictions 4 All electrical wiring should be done by licensed electricians in accordance wi...

Страница 17: ...sure to drop to zero before ser vicing WARNING Provision should be made to prevent water damage from any eventual leaking of boiler or com ponents Install near a floor drain 2 On automatic feed units...

Страница 18: ...end life 2 If generator is undersized for its application heaters will be over worked and reach end of life sooner 3 Element has been overheated due to excessive scale build up The scale acts as an i...

Страница 19: ...50Hz 193 300175 002 Motor only used in ES 38020 115V 60Hz 193 300175 004 Strainer used in ES 38020 351 118664 001 V Band Mount used in ES 38002 ES 38020 355 300174 001 Solenoid Valve used in ES 38002...

Страница 20: ...0 amp 600V 128 121133 066 60 amp 600V 128 121133 067 Fuse Block 35 60 amp 60 amp 600V 129 047445 002 Power Terminal Blocks 3 pole 115 amp 1 line circuit 1 load circuits 303 071809 032 3 pole 175 amp 1...

Отзывы: