Remote Operation
5.6.2
Specific GPIB Commands for 62012P Series
5.6.2.1 ABORT
Subsystem
ABORt
Description:
It sets all output state to “OFF”.
Syntax:
ABORt
5.6.2.2 CONFIGURE
Subsystem
(1) CONFigure: TTLport
Description:
It sets the output value for TTL Port.
Syntax:
CONFigure:TTL
<NR1>
Parameter:
<NR1>
Example:
CONF:TTL 0
CONF:TTL 255
Query Syntax: CONFigure:TTL?
Return Parameter: <NR1>
Query Example: CONF:TTL?
It returns the output value of TTL Port.
Return Example: 0 or 255
(2) CONFigure:BEEPer
Description:
It sets the beeper to ON or OFF.
Syntax:
CONFigure:BEEPer
ON
CONFigure:BEEPer OFF
Parameter:
ON/1, OFF/0
Example:
CONF: BEEPer ON
CONF: BEEPer OFF
Query Syntax: CONFigure:BEEPer?
Return Parameter: <NR1>
Query Example: CONF:BEEPer? It returns the beeper control status.
Return Example: 0 or 1
(3) CONFigure:REMote
Description:
It sets the remote control status (valid for RS232C only).
Syntax:
CONFigure:REMote
ON
CONFigure:REMote
OFF
Parameter:
ON/1, OFF/0
Example:
CONF:REM ON It is set to remote control.
(4) CONFigure:OUTPut
Description:
It sets the output voltage/current.
Syntax:
CONFigure:OUTPut ON
CONFigure: OUTPut OFF
Parameter:
ON/start output, OFF/stop output
Example:
CONFigure: OUTPut
The power supply starts output.
CONFigure: OUTPut OFF The power supply stops outpu.
Query Syntax: CONFigure: OUTPut?
5-9