![Christie LED012-CP-R Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/christie/led012-cp-r/led012-cp-r_installation-and-setup-manual_2603529025.webp)
Installing and configuring the Remote Power
Supply Rack Shelf
Use the following instructions to install and configure the Remote Power Supply Rack Shelf external
power supply.
Mounting the Remote Power Supply Rack Shelf
The power system must be mounted in a clean and dry environment. Sufficient free space must be
provided at the front and rear of the power system.
Warning! If not avoided, the following could result in death or serious injury.
•
This product must be installed within a restricted access location not accessible by the general
public.
1. Find a location in the rack for a 3U device.
2. Attach the Remote Power Supply Rack Shelf to the rack.
To ensure a proper electrical bond between the system chassis and the relay rack use thread-
forming mounting screws and star washers.
Inserting the power modules into the Remote Power Supply
Rack Shelf
The power modules, or rectifiers, convert an AC power source into the DC current required by the
product.
1. Remove the cover from the rectifier slot.
2. Slide the power module into the front of the chassis until it clicks into place.
3. To lock the power module, lift the handle and snap it into place.
4. Repeat steps 1 to 3 for each rectifier in the Remote Power Supply Rack Shelf.
Connecting the LED tile power cables to the Remote Power
Supply Rack Shelf
To power the Velvet CorePlus (Remote Power) LED Display System tiles, connect the cables between
the tiles and the Remote Power Supply Rack Shelf.
1. Connect the main power cable to the Remote Power Supply Rack Shelf.
2. Connect the cabinet power cable to the main power cable.
If the power cord supplied with your product is not long enough to connect the first display
panel in an array to the Remote Power Supply Rack Shelf module, you must purchase a power
cord of an adequate length. Christie recommends one of the pre-terminated power cables
offered as Christie accessories, or that you create a custom cable using the Christie Main
Power Cable Spool (P/N 154-122106-XX), Connector Kit (P/N 154-125109-XX), and Molex
Crimping Tool (P/N 154-124108-XX). For more information on the Molex Crimping Tool, see the
Molex documentation.
3. Plug the Remote Power Supply Rack Shelf into the building outlets in the wall or the floor.
Installation and setup
Velvet LED Display System Installation and Setup Guide–CorePlus Series (Remote Power)
25
020-102423-01 Rev. 1 (06-2018)
Copyright
©
2018 Christie Digital Systems USA, Inc. All rights reserved.