Managing automation
Automation controls playback, the projector, and external devices. The Christie IMB includes built-in
support for some external automation devices. If the device is not supported, you can use the serial-
over-Ethernet protocol to send automation commands.
This section provides instructions for managing and defining:
•
Macros: A macro is a list of actions that you define. For example, opening the curtains or
turning on the house lights at the end of playback. A macro can be activated by a global
trigger, or it can be added to a playlist.
•
Device input triggers: Input cues wait for events such as a general purpose input (GPI) state
change or an Ethernet message. An input cue in a playlist delays playback until an event
occurs. In a global trigger, a macro runs when an input cue event occurs. These are the
available input cues:
Automation Device
Action
Description
Projector
Lamp Off Event
An event starts when the lamp
turns off.
IMB automation
Serial String Input
Waits for a serial string.
IMB automation
GPI Wait
Waits for a GPI event. Not
available on Solaria One or
Solaria One+.
•
Global triggers: A global trigger combines an input cue with a macro. When the predefined
event for the input cue occurs, the output macro is triggered. For example, a fire alarm input
signal stopping playback to stop and turning on the house lights. A global trigger is always
active and is not dependent on specific playlist definitions.
Available macro actions
These are the macro actions that are available to control automated events:
Action Item
Available Actions
Description
Automation
Set Global
Allows you to set a global variable that can be used in
automation scripting (intended for advanced scripting by
Christie)
Generates a projector log entry when an automation macro
runs
Get Global
Allows the automation script to read the value of a global
variable (intended for advanced scripting by Christie)
Set GPO
Sets the specified GPO pin to high or low
Pulse GPO
Pulses the specified GPO pin
Christie IMB-S3 User Guide
33
020-102584-04 Rev. 1 (02-2020)