Service setups
DHD410S Service Manual
16
020-001481-01 Rev. 1 (10-2018)
Adjusting the phosphor index
After replacing main board, combiner, and upgrading firmware, proceed with the phosphor index
adjustment.
To set up for the phosphor index adjustment, follow the steps below.
1. Project the 64 Gray RGBW test pattern.
2. Enter
Service mode
.
See
3. Select
Wheel Index (2x)
or select
Wheel Index (3x)
.
4. Select
Phosphor Index
.
5. Set up for the phosphor index value.
Only confirm the blue color as the other color levels are not taken into account.
a. Adjust the index upwards until blue does not appear smooth.
b. Record the a index value.
c. Adjust the index downwards until blue does not appear smooth.
d. Record the b index value.
e. Set the index value to (a+b)/2.
Warning!
If not avoided, the following could result in death or serious injury.
• Do not look into the projector lens when the laser is on. The bright light may result in permanent
eye damage.
ID
Part name
Description
1
Test equipment
Video generator
2
Test pattern
64 Gray RGBW
3
Inspection items
• Check if the blue color level is supersaturated.
• If the blue color level is supersaturated, the 64 Gray RGBW test pattern
appears blurred and fuzzy.
4
Criteria
• Blue colors in 64 Gray RGBW test pattern appear sharp and clear.
• No noise is visible on the screen.