Command
Description
Values
246 = Yellow
247 = Diagonal Lines
248 = Dark Segmented Ramp
249 = Bright Segmented Ramp
255 = Off
EVT–Event Manager
Retrieves a list of log messages for the current AC cycle from the projector.
Commands
Command
Description
Values
EVT
Returns all events starting from the most
recent event on the projector back to AC
start. (Read-only)
—
EVT <max>
Returns a set number of events starting
from the most recent event on the projector
going back to AC start. (Read-only)
max = Maximum number of events to
return
EVT <start
timestamp>
Returns all events from <start timestamp>
back to current time. (Read-only)
start timestamp = String in the following
format:
yyyy = mm-dd hh:mm:ss
EVT <start
timestamp> <end
timestamp>
Returns all events between two specific
timestamps. (Read-only)
start timestamp = String in the following
format:
yyyy = mm-dd hh:mm:ss
end timestamp = String in the following
format:
yyyy = mm-dd hh:mm:ss
Examples
Retrieve all events since last AC start:
(EVT)
Result:
(EVT!000 "2013-03-17 04:47:18.340" "OK" "Setting Time to 06:47:17")
(EVT!002 "2013-03-17 04:01:13.855" "Error" "(SST+TEMP?002) Air Intake Temperature
(Temp 2) = Communication fault (shutdown)")
(EVT!003 "2013-03-17 04:01:13.824" "Error" "(SST+TEMP?000) Integrator Rod Temperature
(Temp 1) = Communication fault (shutdown)")
(EVT!"--END--")
Retrieve two most recent events:
Serial API commands
Crimson and Crimson Mirage Technical Reference–Serial Commands
26
020-102660-01 Rev. 1 (07-2018)
Copyright
©
2018 Christie Digital Systems USA, Inc. All rights reserved.
Содержание Crimson
Страница 1: ...Technical Reference 020 102660 01 Crimson and Crimson Mirage Serial Commands ...
Страница 55: ......