background image

Technical Reference

020-102661-04

Crimson and Crimson Mirage

Status System

Содержание Crimson HD25

Страница 1: ...Technical Reference 020 102661 04 Crimson and Crimson Mirage Status System...

Страница 2: ...ed modified or approved by Christie for such use g Except where the product is designed for outdoor use problems or damage caused by use of the product outdoors unless such product is protected from p...

Страница 3: ...F 5 System Group SST SYST 6 Signal Group SST SIGN 12 Light Group SST LGHT 13 Version Group SST VERS 15 Cooling Group SST COOL 17 Temperature Group SST TEMP 20 Serial Group SST SERI 23 Crimson and Crim...

Страница 4: ...ex within each group Model name Crimson HD25 Crimson WU25 Crimson HD31 Crimson WU31 Mirage HD25 Mirage WU25 Product documentation For installation setup and user information see the product documentat...

Страница 5: ...age Service Guide P N 020 102733 XX Crimson and Mirage Serial Commands Guide P N 020 102660 XX Status system states The status system has three states to indicate the health of the device OK No known...

Страница 6: ...alth for Crimson Status State Value Description 0 Projector Hours hours minutes Displays the total amount of time that the projector has been on including warm up and cool down times This does not inc...

Страница 7: ...built in self test failed 10 System ID Board OK The device has been properly detected and initialized Unknown The status of the device is unknown Communication Fault Cannot communicate with the devic...

Страница 8: ...eports a fan failure but no over temperature shutdown or high temperature alarm is reported Overtemperature The power supply reports a high temperature alarm but reports no fan failure Overtemperature...

Страница 9: ...Cannot successfully program the main control board 32 Power Supply Output Voltage voltage V Displays the output voltage reading when the housekeeping board HKB is ready Unknown The status of this outp...

Страница 10: ...processor Runtime fault The image processor experienced an unrecoverable failure during runtime 50 51 52 Formatter Red Formatter Green Formatter Blue Off The formatter is in standby without any cached...

Страница 11: ...n Fault Cannot detect the color sensor board Initialization Fault Cannot properly initialize the color sensor board 113 Combine ID Board OK The device has been properly detected and initialized Unknow...

Страница 12: ...he card does not have a single input port input type No Signal No signal is detected Where input type DP HDMI DVI 3G SDI input type active window v sync rate status Where input type DP HDMI DVI 3G SDI...

Страница 13: ...not locked and or in phase with the 3D video signal s The system is using the internal v sync signal instead but may have L R swapped No 3D Sync using internal sync Cannot detect an external 3D sync T...

Страница 14: ...iode current Red1 Diode current Red2 Diode current Red3 Diode current Red4 Diode current Green Red A Diode current Green Red B Diode current Green Red C Diode Current Blue current mA Displays the curr...

Страница 15: ...and other peripheral Version Group SST VERS The Version Group provides values and fault conditions related to software and hardware versions for Crimson Status State Value Description 0 Main Control B...

Страница 16: ...r is in standby N A The formatter has never been turned on 7 8 Option Card 1 HW Version Option Card 2 HW Version name level mod name Short name of the board level Version of the board mod Modification...

Страница 17: ...e color sensor board Unknown Cannot retrieve the hardware version 60 Combiner Fan SW Version version Displays the firmware version running on the combiner fan board Unknown Cannot retrieve the firmwar...

Страница 18: ...Unknown The tachometer reading is unavailable tach RPM Low RPM Fan tachometer reading is lower than the minimum recommended speed For the low RPM threshold see Crimson and Mirage Specifications Guide...

Страница 19: ...ays the current tachometer reading Off Fan is off Unknown The tachometer reading is unavailable Off Overridden Fan is off The fan speed has been changed from its default recommended value tach RPM Ove...

Страница 20: ...is on The fan speed has been changed from its default recommended value tach RPM Low RPM Fan tachometer reading is lower than the minimum recommended speed For the low RPM threshold see Crimson and M...

Страница 21: ...ature value C Displays the current temperature of the sensor Unknown Temperature reading is unavailable value C Low Temperature Temperature is sitting inside the warning band value C High Temperature...

Страница 22: ...Fault shutdown Cannot retrieve the temperature from sensor 29 Main Control Board FPGA Temperature value C Displays the current temperature of the sensor N A Temperature reading is unavailable value C...

Страница 23: ...s the electronic serial number of the main control board Missing S N Cannot retrieve the value because the serial number was not programmed into the board correctly 1 Backplane S N serial number Displ...

Страница 24: ...orrectly 14 15 Housekeeping Board S N Keypad Display S N serial number Displays the electronic serial number of the board Unknown The serial number is unavailable because the board is not ready Missin...

Страница 25: ...6877 8737 Africa ph 27 0 11 510 0094 Korea Seoul ph 82 2 702 1601 Japan Tokyo ph 81 3 3599 7481 India ph 91 080 6708 9999 Germany ph 49 0 221 99512 0 France ph 33 0 1 41 21 44 04 Russia ph 36 0 1 47 4...

Страница 26: ......

Отзывы: