Mode
Description
Standby
• C electronics remain on standby with the light engine off
• Laser optical sub-systems (LOS) and thermo-electric cooler (TEC) devices are
off
• Fans run at reduced speed
Projector on
• C electronics and light engine are on
• LOS and TEC devices are off
• Chiller is on
Light source on
• C electronics and light engine are on
• LOS and TEC devices are on
• Fans run at full speed
• Chiller is on
Setting up the chiller unit
For detailed information on setting up the chiller, refer to the documentation provided by the
manufacturer of the chiller unit.
Once the chiller is connected to AC and the chiller communication cable is connected to the projector,
the projector controls the chiller automatically to maintain the required coolant temperature.
Connecting the chiller communication cable
The chiller communication cable is connected through a signal terminal located at the front of the
chiller unit. The connection allows communication between the projector and the chiller.
The chiller communication cable includes an RS-232 connector, attached cable with rubber grommet,
and three terminal connectors.
The installation of the chiller communication cable must be performed by a Christie qualified technician.
1. Remove the cover for the signal terminal by unscrewing the two cover screws.
Installing and setting up
C RGB PLF Installation and Setup Guide–CP4450-RGB
30