manualshive.com logo in svg
background image

At the heart of Christie’s CP Series Digital Cinema projector line 
are Christie’s CDXL high performance short-arc Xenon lamps. 
These lamps have been optimized for use with the CP Series 
Digital Cinema projectors. With increased brightness in the same 
form factor as standard cinema grade lamps, CDXL lamps provide 
higher output and brightness in a more cost-efficient package.

To get a true representation of color in any professional 
environment, you need a truly remarkable light source. Christie’s 
Xenon Arc Lamps offer stable color temperature, a wide range 
of power levels and excellent color rendition. Christie lamps are 
backed by the best warranty in the industry.

Xenon Lamp Listing

High performance short arc Xenon lamp solutions

Содержание CDXL-20

Страница 1: ...standard cinema grade lamps CDXL lamps provide higher output and brightness in a more cost efficient package To get a true representation of color in any professional environment you need a truly remarkable light source Christie s Xenon Arc Lamps offer stable color temperature a wide range of power levels and excellent color rendition Christie lamps are backed by the best warranty in the industry ...

Страница 2: ... at Warner Bros Movie World installed two high resolution Christie CP2000 projectors in the main theatre with an uncompressed digital video server in a custom configuration The projectors display high resolution stunning 3D images onto the 15m 49ft wide Harkness screen The Christie CP2000 projectors are amazing They re brilliant with their true to life colors They re an absolute pleasure to work w...

Страница 3: ...2 ...

Страница 4: ...ns WAVELENGTH DIAGRAM Spectral distribution diagram Spectrum comparison between Xenon lamp and daylight Variation spectral distribution corresponding to input variation Luminous intensity distribution curve Luminous intensity distribution curve along the arc axis Construction of a Xenon short arc lamp 3 X E N O N S H O R T A R C L A M P C H A R A C T E R I S T I C S ...

Страница 5: ... of the top movie theatre operators in the U S Cinemark s primary focus has always been to give its customers a fun and exciting movie going experience The Christie CP Series Digital Cinema projectors powered by CDXL Xenon short arc lamps set new levels of performance for Digital Cinema technology Choices in brightness levels and power levels offer flexibility for a variety of screen sizes in exis...

Страница 6: ...zontal º 5º Base surface temperature ºC 200ºC max Forced air cooling m s 10 to 13 CDXL 30 003 000599 02 TECHNICAL DATA Rated input power W 3000 Rated current A 110 Operating current range A 90 120 Rated voltage V 27 Cold arc gap mm 5 5 Lamp length L1 mm 403 Improved performance Cost efficient Purpose built for cinema applications Lamp length L2 mm 350 LCL L3 mm 161 5 Bulb diameter mm ø 60 Base dia...

Страница 7: ...tal º 5º Base surface temperature ºC 200ºC max Forced air cooling m s 10 to 13 CDXL 60 003 000601 02 TECHNICAL DATA Rated input power W 6000 Rated current A 155 Operating current range A 105 165 Rated voltage V 39 Cold arc gap mm 8 Lamp length L1 mm 417 Improved performance Cost efficient Purpose built for cinema applications Lamp length L2 mm 381 LCL L3 mm 165 5 Bulb diameter mm ø 70 Base diamete...

Страница 8: ... 10 CXL 45 CXL 10S CXL 50SC CXL 10SC CXL 60 CXL 1600A CXL 60SC CXL 16S CXL 70 CXL 16SC CXL 70SC CXL 20 CXL 20R Christie Core Lamps CXL 20 CXL 25 CXL 30 CXL 40 CXL 45 CXL 60 CXL 20SC CXL 25 CXL 2500LC CXL 25SC CXL 30 CXL 30R CXL 30SC CXL 40 CXL 40SC Christie understands the cinema industry We know our customers personally With no margin for error the show must always go on and our CXL Short Arc Xen...

Страница 9: ...Hoyts Cinema Australia CXL short arc Xenon lamps for cinema projection 8 ...

Страница 10: ... 235 236 236 235 365 375 342 370 Lamp length between connector faces mm 275 275 205 222 222 205 320 320 302 320 Lamp length from rear connector face to arc center mm 125 125 96 5 96 5 96 5 96 5 145 145 147 145 Bulb diameter mm 40 45 40 40 48 48 55 55 60 55 Cathode pin diameter mm 12 M14XP1 5 5 16 18UNC 5 16 18UNC 5 16 18UNC 5 16 18UNC 12 M14XP1 5 7 9 12 Anode pin diameter mm 10 14 11 N A N A 11 10...

Страница 11: ... 37 43 43 7 0 7 0 6 0 7 0 6 5 7 0 7 0 7 0 7 0 8 0 8 0 9 0 9 0 11 0 11 0 403 433 345 403 342 428 433 410 428 433 410 417 433 417 433 350 380 300 350 302 382 380 370 380 380 370 381 392 381 392 165 171 147 165 147 171 170 174 5 170 170 171 170 176 170 176 60 57 60 60 60 70 70 70 70 80 70 80 80 80 80 M14XP1 5 14 7 9 M14XP1 5 7 9 14 M14XP1 5 7 9 14 M14XP1 5 7 85 M14XP1 5 7 85 M14XP1 5 7 85 14 13 9 4 1...

Страница 12: ...3000W HTP OFR LTIX 3000W HTPCH 3000 CXL 30R XBO 3000W H OFR LTIX 3000W HCH 3000 CXL 30SC XBO 3000W HS OFR LTIX 3000W HSXH 4000 CXL 40 XBO 4000W HTP OFR LTIX 4000W HTPCH 4000 CXL 40SC XBO 4000W HS OFR LTIX 4500W HSCH 4500 CXL 45 NONE NONE 5000 CXL 50SC NONE L5000W HS 6000 CXL 60 NONE LTIX 6000W HTP 6000 CXL 60SC NONE LTIX 6002W HS 7000 CXL 70 NONE NONE 7000 CXL 70SC XBO 7000W HS OFR LTIX 7000W HSCH...

Страница 13: ...cipated credit together with completed warranty form 3 Bulb must have been operated with the correct polarity not below rated minimum current nor above maximum rated power in accordance with applicable air cooling requirements and other operating conditions 4 If the bulb is operated with a spherical reflector the reflected cathode hot spot must not be superimposed on either of the bulb s electrode...

Страница 14: ...ould cause injury if it bursts Wear a protective mask protective gloves and a thick long sleeved shirt when the lamp is handled or installed and removed to from the lamp house The protective mask which covers the carotid must be made with thicker than 2mm polycarbonate or another material with same strength or more Gloves and a thick long sleeved shirt must be made with ripping proof and piercing ...

Страница 15: ... minutes after the lamp is turned off Otherwise it could cause an injury if it bursts Remove the lamp from the lamp house after making sure it has been turned off for more than 15 minutes and the lamp and lamp house have cooled down Otherwise it could cause an injury or burn if the lamp bursts Use a suitable lamp house and power supply ballast Operate a lamp in the range of wattage designated Stor...

Страница 16: ...ed Performance specifications are typical Due to constant research specifications are subject to change without notice Printed in Canada on recycled paper 2316 Feb 08 Corporate offices Worldwide offices USA Cypress ph 714 236 8610 Canada Kitchener ph 519 744 8005 United Kingdom ph 44 118 977 8000 Germany ph 49 2161 664540 France ph 33 0 1 41 21 44 04 Hungary Eastern Europe ph 36 0 1 47 48 100 Sing...

Отзывы: