Replacing the lamp module
The lamp module acts as the projector's illumination source directing light into the integrator module.
It mounts to the lamp cartridge module, which contains three lamps per module.
Replace the lamp module when the lamps are nearing the end of their operational lives or have burnt
out.
Estimated replacement time: 2 minutes for servicing a single lamp module
1. To open the lamp door, loosen the two captive screws and open the door.
2. Loosen the captive screw from the lamp cartridge containing the lamp module you want to
replace.
3. Use the handle to pull out the lamp cartridge.
4. Loosen the four lamp module mounting captive screws and remove the module.
5. Install the new lamp module and fasten with the four captive screws.
6. Slide the new cartridge back in until you feel the connector engaging.
7. Tighten the previously removed captive screw to secure the lamp cartridge.
Make sure the captive screw is fully seated (tightened) or a loose connection between the lamp
cartridge and the projector could occur.
8. Close the lamp door and tighten the two captive screws.
Repairing a lamp module lens
Use the cartridge repair kit (P/N: 003-005165-XX) when a lamp explosion has occurred, causing
damage to the lamp module lens.
Estimated replacement time: 7 minutes