6.3 Electrical Interface
6.3.1 Inputs
6.3.2 Outputs
Relay Outputs
Only Qualified Electricians should connect primary voltages.
Parameter
Symbol
Min.
Norm.
Max.
Unit
Input voltage range
V
max
0
30
V
Isolation voltage
V
iso
1000
V
ON voltage level
V
H
3
30
V
OFF voltage level
V
L
1
V
Min. ON time
t
min
1
ms
Pull-up current
I
PU
10
mA
Parameter
Pin
Symbol
Min.
Nom.
Max.
Unit
Small relay contact ratings (continuous A)
I
CMax
-
-
1
A
Small relay contact ratings
1 to 12
V
CMax
-
-
220
V
DC
Large relay contact ratings (continuous A)
I
CMax
0.1
8
A
Large relay contact ratings (resistive)
13 & 14
V
CMax
240
V
AC
Wire size accepted - Clip terminals
Gauge
28
-
16
AWG
Figure 6-2 Opto-Isolated Inputs
Figure 6-3 Relay Outputs