LSE–Last System Error
Retrieves the last recorded system error.
Commands
Command
Description
Values
LSE?
Displays the last system error.
(Read-only)
1 = The light source did not engage after five attempts
3 = The light source went out unexpectedly
4 = Fan failure
5 = Over temperature
LVO–Lens Shift Vertical
Adjusts the vertical lens offset.
Commands
Command
Description
Values
LVO <position>
Adjusts the vertical location of the lens.
n = Increases vertical location of the lens by
one
p = Decreases vertical location of the lens
by one
Examples
Move the lens to position 500 on the vertical axis:
(LVO 500)
MBE–Message Box Enable
Enables or disables the displaying of groups of message boxes on the on-screen display.
Commands
Command
Description
Values
MBE+USER <0 | 1>
Enables or disables displaying message
boxes directly triggered by user actions, for
example gamma or lens control message
boxes.
0 = Disables displaying message boxes
directly triggered by user actions
1 = Enables displaying message boxes
directly triggered by user actions (Default)
Serial API commands
GS Series 599 Serial Commands Technical Reference
39
020-102403-02 Rev. 1 (04-2017)
Copyright
©