Industrial PC
Instruction Manual
Document No.: PA10009320
17 / 33
Sep. 2021, Revision 00
5.1
Connection of the power supply
Use conductors with a cross-section of 0.75 mm² to 1.5 mm². Use the MC 1,5/ 3-STF-3,5
BKBDWH:GND Q PCB connector from Phoenix.
Strip the insulation from the individual wires of the conductor (1). Insert these into the connection con-
tacts (3) of the PCB connector and tighten the screw contacts (2) with a screwdriver and a maximum
torque of 0.3 Nm.
The rear view (4) of the connector is shown for clarification.
Illustration 3: Connection of the power supply
5.2
Earth Connection
NOTICE
Earthing not connected
Not guaranteed functionality of the device
➢
All earth connections must be connected to an earth point
5.3
Mounting Industrial PC
Step 1:
Hook the Industrial PC onto the fastening rail at
an angle from above. Press the Industrial PC
down until it hooks into place.
Step 2:
The industrial PC hangs on the fastening rail.
Illustration 4: Mounting Industrial PC Step 1