Chore-Time 52410-6 Скачать руководство пользователя страница 1

Introduction

The Chore-Time Water Regulator is designed to regulate water 

pressure for Chore-Time Layer and Brood Grow Nipple 
Watering Systems. There is a model for manual adjustment of 
the regulator and one for PDS™ controller adjustment.

Installation Guidelines

Each water pressure regulator is capable of suppling one tier 

(two lines) up to 600’ 

[182.8 m]

. Systems over 600’ 

[182.8 m]

 

require two regulators per tier (one per line).

In Modular Manure Belt Brood Grow installations using air 

drying tubes; two regulators per tier must be used no matter 
what the cage row length. The air tube prevents water line 
connection from one side of the cage row to the other.

The regulator assemblies should be mounted on one side of the 

cage row. This location should be easily reachable from the 
aisle for adjustment purposes and should not interfere with 
other equipment (DBS system, manure belts, egg belts, belt 
take ups, feeding system etc.). The regulator assemblies 
should also be located so they are protected from damage. 
Installation of the regulator assemblies should not be 
attempted until the location of all other equipment is 
established.

The height of the stand tube/air breathers must also be taken into 

consideration when positioning the regulator assemblies. It is 
important to be able to maintain this height so the full 
operating range of the regulator can be utilized.

It is important to install the regulator in a way that will allow the 

assembly to be turned off the nipple pipe line. If removal is 
necessary the stand tube/air breather will need to be removed 
before turning the regulator off the nipple pipe line.

It is recommended to install the regulator assembly equal to or 

slightly higher than the nipple water line. Installing the 
regulator with this recommendation will aid in removal of 
unwanted air in the system.

Single regulator installations (feeding two lines per tier) should 

be plumbed so the output from the regulator flows through the 
same number of restrictions (ells) to feed both lines. The same 
number of restrictions will assure equal volume of water to 
both lines. Equal volume of water is especially important in 
brood grow installations so the flush times (from one line to 
another) are close to the same.

In layer systems the connection between the regulator and the water supply inlet is made with a 3/4" 

[1.91 cm] 

flexible hose assembly. This hose connects between the regulator and the water supply. The hose and connectors 
must be of high quality and rated for the incoming water pressure.

In brood grow systems use the provided 5/8" x 36" 

[1.59 x 91.4 cm]

 regulator inlet supply hose. This hose connects 

between the regulator and the water supply.

Under 600 Ft (182.9 M)
One Regulator Per Tier

Cage Row

Over 600 Ft (182.9 M)
Two Regulators Per Tier

Cage Row

WATER SUPPLY INLET

WATER SUPPLY INLET

Modular manure Belt (MMB)
One Regulator Per Tier

Cage Row

WATER SUPPLY INLET

Additional ells will be needed for routing

around and thru the manure belt framing.

8141 Ell 3/4" PVC SXS

8141 Ell 3/4" PVC SXS

8083 3/4" PVC Pipe

Supply Hose

Supply Hose

8083 3/4" PVC Pipe

Supply Hose

7558 Ell SxT

(Top or

Bottom Tier)

7558 Ell SxT

(Top or

Bottom Tier)

7558 Ell SxT

(Top or

Bottom Tier)

7538 Tee

SxSxT

7538 Tee

SxSxT

7538 Tee

SxSxT

7187 Hose

Clamp

50401 Hose

Adapter

7543 Nylon

Adapter

7543 Nylon

Adapter

7187 Hose

Clamp

50401 Hose

Adapter

7187 Hose

Clamp

50401 Hose

Adapter

7543 Nylon

Adapter

7538 Tee 3/4" PVC SXSXS

Figure 1. Layout Guidelines

Watering Regulator for Cage Systems

Manual Adjustment Part Number 52410-6

PDS™ Adjustment Part Number 52410-7

Chore-Time Poultry Production Systems, a Division of CTB, Inc.

P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A.

Phone (574) 658-4101 • Fax (877) 730-8825

E-Mail: [email protected] • Internet: www.choretimepoultry.com

MW1642D