background image

FS-8705-12 Federal Signal Ultravoice - Electronic Siren Controllers Driver Manual 

Page 25 of 30 

© 2021 CHIPKIN AUTOMATION SYSTEMS 

Appendix B.

 

Troubleshooting-Tips 

 

This section is blank.  

 

 

ERROR MESSAGE 

EXPLANATION AND CORRECTIVE ACTION 

We have shown place holders for the 
parts of the message which change. 

 

%s is a place holder for a text string. 

%d is a place holder for a number 

%c is a place holder for an alpha 
character. 

 

 

FSU_ESC:#1 Err FSU_ESC_Function='%s' is 
unknown 

 

The driver has been configured incorrectly. 

 

The Map Descriptor parameter 

FSU_ESC_Function_Name

  must be specified 

correctly. Review Chapter 4 and the examples.  

 

Correct the configuration and then download the 
corrected configuration file and reset the 
FieldServer for the changes to take effect. 

 

FSU_ESC:#2 Err. The Function Name must 
be specified. 

See Error #1 

FSU_ESC:#3 Err. Zone command out of 
range. %s[%d]Value=%d 

 

Where %s[%d] specifies a Data Array and 
offset. 

Valid Entries in the Data Array are 1-4 for zones A-

 

The most likely cause for this message is either the 

driver has started up and there are zero’s in the 

Data Arrays or the other protocol has written a 
number to the FieldServer that is out of the valid 
range. 

Содержание FS-8705-12

Страница 1: ...salesgroup1 chipkin com Tel 1 866 383 1657 2021 CHIPKIN AUTOMATION SYSTEMS Driver Version 1 01a Document Revision 4...

Страница 2: ...ERS SERIAL DRIVER CLIENT 9 4 1 DATA ARRAYS DESCRIPTORS 9 4 2 CLIENT SIDE CONNECTION DESCRIPTIONS 10 4 3 CLIENT SIDE NODE DESCRIPTORS 11 4 4 CLIENT SIDE MAP DESCRIPTORS 12 FieldServer Related Map Descr...

Страница 3: ...ent As a client the driver can poll for status information and send commands to the FSU controller The driver is a serial driver using a RS232 serial port to connect between the FieldServer and the CH...

Страница 4: ...voice Electronic Siren Controllers Driver Manual Page 4 of 30 2021 CHIPKIN AUTOMATION SYSTEMS Supported Functions ARM CANCEL VOICE DISARM ZONEA D REPORT MSG_A P WAIL P_WAIL A_WAIL STEADY P_STEADY A_ST...

Страница 5: ...MATION SYSTEMS Status Items Monitored with Report Function Siren Type Function State Code running Unit ID Amplifier status for each amp in the unit depending on siren type Audio A Audio B Master Curre...

Страница 6: ...pped with this driver FS 8705 12 Driver Manual 2 2 Provided by the Supplier of 3rd Party Equipment Required 3rd Party Hardware PART DESCRIPTION Required 3rd Party Software Required 3rd Party Configura...

Страница 7: ...figure 1 Figure 1 RJ11 to DB9 Connector for Serial Communication b Build the connector shown above and connect the RJ11 end to the port labeled RS232 on the UV panel and the DB9 end to the computer I...

Страница 8: ...er Manual Page 8 of 30 2021 CHIPKIN AUTOMATION SYSTEMS 2 The second step is to connect the panel to the FieldServer using a CAT 5E patch cable with a RJ11 connector on the panel end and a RJ45 on the...

Страница 9: ...ntrollers Serial Driver communications the driver independent FieldServer buffers need to be declared in the Data Arrays section the destination device addresses need to be declared in the Client Side...

Страница 10: ...aud Specify baud rate Driver Supports 110 300 600 1200 2400 4800 9600 19200 28800 38400 57600 115200 Baud Vendor Equipment Supports 1200 Baud Parity Specify parity Driver Supports Odd Even None Vendor...

Страница 11: ...for node Up to 32 alphanumeric characters Node_ID Station address of physical server node This parameter is not used directly by the driver We recommend that a unique Node ID s be given to each node...

Страница 12: ...ation in Data Array 0 to maximum specified in Data Array section above Function Function of Client Map Descriptor RDBC WRBC WRBX Passive_Client Driver Related Map Descriptor Parameters COLUMN TITLE FU...

Страница 13: ...TEMS FSU_ESC_Function_Name Used to define the command to be sent to the controller GENERIC ARM CANCEL VOICE Q_TEST DISARM ZONE REPORT RESET MSG WAIL P_WAIL A_WAIL STEADY P_STDY A_STDY AUX PHASE PHASE...

Страница 14: ...Interval Data_Array_Name Data_Array_Offset Node_Name Function Length FSU_ESC_Function_Name ReadAll 1 0s DA_REPORT 0 SirenNode Rdbc 34 Report Length is obtained from Appendix B 1 Read this data every 1...

Страница 15: ...a reset command to the controller The value written doesn t have to change to trigger the command It is the update of the Data Array element that triggers the command Map_Descriptors Map_Descriptor_N...

Страница 16: ...for PHASE or PHASE Each time one of these commands is executed the driver sends the appropriate message to the controller In this example the commands wait to be triggered by some other protocol updat...

Страница 17: ...r Status A As Ascii Char See Table 4 9 Sensor Status B As Ascii Char See Table 4 10 Sensor Status C As Ascii Char See Table 4 11 Status Amp 1 0 Ok 1 Bad or Inactive 12 Status Amp 2 0 Ok 1 Bad or Inact...

Страница 18: ...ass 35 Rotation 0 Occurred 1 Not Occurred 36 Not Used 0 Ok 1 Bad or Inactive 37 Spare 0 Ok 1 Bad or Inactive 38 False Alarm 0 Occurred 1 Not Occurred Table 2 Unit Type DATA ARRAY VALUE ASCII EQUIVALEN...

Страница 19: ...N UV 14 79 O UV 15 80 P UV 16 Table 3 Function State DATA ARRAY VALUE ASCII EQUIVALENT MEANING 48 0 Wail 49 1 Pulsed Wail 50 2 Alt Wail 51 3 Steady 52 4 Pulsed Steady 53 5 Alt Steady 54 6 Aux 55 7 Al...

Страница 20: ...Code 13 78 N Code 14 79 O Code 15 80 P Code 16 81 Q Code 17 82 R Code 18 83 S Code 19 84 T Code 20 85 U Code 21 86 V Code 22 87 W Code 23 88 X Code 24 89 Y Code 25 90 Z Code 26 91 Code 27 92 Code 28 9...

Страница 21: ...IPKIN AUTOMATION SYSTEMS 107 k Code 43 108 l Code 44 109 m Code 45 110 n Code 46 111 o Code 47 112 p Code 48 113 q Code 49 114 r Code 50 Table 4 Status Codes DATA ARRAY VALUE MEANING 1 0001 2 0010 3 0...

Страница 22: ...AUTOMATION SYSTEMS 5 Configuring the FieldServer as a ICS1 2 Driver Server This driver has a server side implemeted but it is used for FieldServer s Quality Assurance program and is not docuemnted or...

Страница 23: ...MMENT 14 Aug 2008 PMC 1 00a 0 Document Created 25 Sept 2008 PMC 1 00a 1 Added connection diagrams and notes Thanks to JH 7 Oct 2008 PMC 1 01a 2 Changed Arrangement of Data and updated some tables Tabl...

Страница 24: ...FS 8705 12 Federal Signal Ultravoice Electronic Siren Controllers Driver Manual Page 24 of 30 2021 CHIPKIN AUTOMATION SYSTEMS Appendix A Advanced Topics This section is blank...

Страница 25: ...red incorrectly The Map Descriptor parameter FSU_ESC_Function_Name must be specified correctly Review Chapter 4 and the examples Correct the configuration and then download the corrected configuration...

Страница 26: ...guration manual has notes on how to do that FSU_ESC 5 Err MSG command not recognized s The Message command speficied in the configuration file must be MSG you cannot specify MSG_A or any other format...

Страница 27: ...cannot specify CODE01 or any other format Read example 3 in chapter 4 for example on how to configure this command Correct the configuration and then download the corrected configuration file and res...

Страница 28: ...ollow up with a call FSU_ESC 18 Err Recieved Cmd s Require DA with name s to Store If this message is printed please take a log send the log to Tech Support using email and follow up with a call FSU_E...

Страница 29: ...ata Arra wasn t a 1 or 2 5 Incremented each time the driver doesn t recognize the command to be sent 6 Increments each time a REPORT query is sent to the controller 7 Total number of bytes sent to the...

Страница 30: ...30 2021 CHIPKIN AUTOMATION SYSTEMS OFFSET DESCRIPTION 16 Number of times a complete but invalid response to the Status Report query are received 17 Increments each time a Report msg is sent and no res...

Отзывы: