4 Measurement Setting
4.4 Setting of Signal Power Level
92
Frequency range: 10MHz-13.5GHz/26.5GHz/43.5GHz/50GHz/67GHz
Frequency resolution: 1Hz
1) Two ways of frequency range setting
a) Specify the start and stop frequency.
b) Specify the center frequency and frequency span.
2) Setting of start and stop frequency
Menu path:
[Stimulus] > [Freq]
Fig. 4.8 Setting of Start and Stop Frequency
3) Setting of center frequency and frequency span
Menu path:
[Stimulus] > [Freq]
Fig. 4.9 Setting of Center Frequency and Frequency Span
Prompt
[Frequency] shortcut key
The frequency can be rapidly set with the
[Frequency]
shortcut key in the functional key zone of the front panel.
4.4 Setting of Signal Power Level
The power level refers to the power level of the output signal of the test port. The power level indicators of the port
of AV3672 series vector network analyzer are as follows.
Table 4.2 Power Level Indicators of Source Output Signal
Frequency range
Source frequency
range (dBm)
Configuration
10MHz ~ 13.5GHz/26.5GHz/43.5GHz/50GHz/67GHz
-25 ~ +20
Standard configuration
10MHz ~ 13.5GHz/26.5GHz
-95 ~ +20
Option:
program-controlled
step attenuator
10MHz ~ 43.5GHz/50GHz
-85 ~ +20
Option:
program-controlled
step attenuator
10MHz ~ 67GHz
-75 ~ +20
Option:
program-controlled
Содержание AV3672 Series
Страница 1: ...AV3672 Series Vector Network Analyzer User Manual China Electronics Technology Instruments Co Ltd...
Страница 3: ......
Страница 4: ...AV3672 Series Vector Network Analyzer Contents...
Страница 5: ......
Страница 124: ...5 Menu 5 1 Menu structure 120 5 1 2 Track Fig 5 2 Track Menu...
Страница 125: ...5 Menu 5 1 Menu structure 121 5 1 3 Channel Fig 5 3 Channel Menu...
Страница 126: ...5 Menu 5 1 Menu structure 122 5 1 4 Excitation Fig 5 4 Excitation Menu I...
Страница 127: ...5 Menu 5 1 Menu structure 123 Fig 5 5 Excitation Menu II...
Страница 128: ...5 Menu 5 1 Menu structure 124 Fig 5 6 Excitation Menu III...
Страница 129: ...5 Menu 5 1 Menu structure 125 5 1 5 Response Fig 5 7 Response Menu I...
Страница 130: ...5 Menu 5 1 Menu structure 126 Fig 5 8 Repsonse Menu II...
Страница 131: ...5 Menu 5 1 Menu structure 127 Fig 5 9 Response Menu III...
Страница 132: ...5 Menu 5 1 Menu structure 128 Fig 5 10 Response Menu V Fig 5 11 Response IV...
Страница 133: ...5 Menu 5 1 Menu structure 129 5 1 6 Calibration Fig 5 12 Calibration Menu...
Страница 134: ...5 Menu 5 1 Menu structure 130 5 1 7 Marker Fig 5 13 Cursor Menu I...
Страница 135: ...5 Menu 5 1 Menu structure 131 Fig 5 13 Cursor Menu II...
Страница 136: ...5 Menu 5 1 Menu structure 132 Fig 5 15Marker Menu III...
Страница 137: ...5 Menu 5 1 Menu structure 133 5 1 8 Analysis Fig 5 16 Analysis Menu I...
Страница 138: ...5 Menu 5 1 Menu structure 134 Fig 5 17 Analysis Menu II...
Страница 139: ...5 Menu 5 1 Menu structure 135 Fig 5 18 Analysis Menu III...
Страница 140: ...5 Menu 5 1 Menu structure 136 5 1 9 System Fig 5 19 System Menu I...
Страница 141: ...5 Menu 5 1 Menu structure 137 Fig 5 20 System Menu I...
Страница 254: ...8 Basis of Network Measurement 8 3 Amplifier Parameter Specifications 250...
Страница 257: ...8 Basis of Network Measurement 8 4 Complex Impedance 253...
Страница 366: ...Appendix Appendix 3 Frequency Offset Measurement 362 Fig 3 13 Test of Return Loss of Mixer LO Port...
Страница 373: ...Appendix Appendix 4 Pulse Measurement 369 Fig 4 9 Receiver gain configuration Dialog Box...