4 Measurement Setting
4.3 Setting of Frequency Range
91
Menu path:
[Trace] > [New Trace]
. Click “
Receivers
” in the dialog box.
2) [New Trace] dialog box (any ratio and non-ratio power measurement)
a)
[Active]
check box
Tick it to create a new trace.
b) [Numerator] zone
Select the numerator of any ratio measurement or the receiver for non-ratio power measurement.
c) [Denominator] zone
Select the denominator of any ratio measurement. The value is 1 in non-ratio power measurement.
d) [Source] box
Select the source signal output port of the analyzer.
e) [Channel Number] box
Select the channel for the new trace.
f) [Create in new window] check box
If this check box is selected, a trace will be created in the new window. If this check box is cleared, a trace will be
created in the current active window.
g) [Auto-Create Window] check box
If this check box is ticked and the number of traces in the window exceeds 8, excessive traces will be automatically
created in a new window.
If this check box is cleared and the number of traces in the window exceeds 8, excessive traces will not be created.
4.2.4 Measurement mode of trace change
The trace must be activated before setting and modification.
1) Change the trace state
Click the
[Track state]
button in the window. The corresponding trace will be activated.
Fig. 4.6 Change of Track Activation State
2) Change the measurement parameter of active trace
Menu path:
[Response] > [Measure]
. The
measure
sub-menu will appear. Or, right-click the trace title bar, and
click [Measure] in the menu, as shown in Fig. 4.7.
Fig. 4.7 Setting of Parameter S Measurement Mode of Activated Trace
4.3 Setting of Frequency Range
Содержание AV3672 Series
Страница 1: ...AV3672 Series Vector Network Analyzer User Manual China Electronics Technology Instruments Co Ltd...
Страница 3: ......
Страница 4: ...AV3672 Series Vector Network Analyzer Contents...
Страница 5: ......
Страница 124: ...5 Menu 5 1 Menu structure 120 5 1 2 Track Fig 5 2 Track Menu...
Страница 125: ...5 Menu 5 1 Menu structure 121 5 1 3 Channel Fig 5 3 Channel Menu...
Страница 126: ...5 Menu 5 1 Menu structure 122 5 1 4 Excitation Fig 5 4 Excitation Menu I...
Страница 127: ...5 Menu 5 1 Menu structure 123 Fig 5 5 Excitation Menu II...
Страница 128: ...5 Menu 5 1 Menu structure 124 Fig 5 6 Excitation Menu III...
Страница 129: ...5 Menu 5 1 Menu structure 125 5 1 5 Response Fig 5 7 Response Menu I...
Страница 130: ...5 Menu 5 1 Menu structure 126 Fig 5 8 Repsonse Menu II...
Страница 131: ...5 Menu 5 1 Menu structure 127 Fig 5 9 Response Menu III...
Страница 132: ...5 Menu 5 1 Menu structure 128 Fig 5 10 Response Menu V Fig 5 11 Response IV...
Страница 133: ...5 Menu 5 1 Menu structure 129 5 1 6 Calibration Fig 5 12 Calibration Menu...
Страница 134: ...5 Menu 5 1 Menu structure 130 5 1 7 Marker Fig 5 13 Cursor Menu I...
Страница 135: ...5 Menu 5 1 Menu structure 131 Fig 5 13 Cursor Menu II...
Страница 136: ...5 Menu 5 1 Menu structure 132 Fig 5 15Marker Menu III...
Страница 137: ...5 Menu 5 1 Menu structure 133 5 1 8 Analysis Fig 5 16 Analysis Menu I...
Страница 138: ...5 Menu 5 1 Menu structure 134 Fig 5 17 Analysis Menu II...
Страница 139: ...5 Menu 5 1 Menu structure 135 Fig 5 18 Analysis Menu III...
Страница 140: ...5 Menu 5 1 Menu structure 136 5 1 9 System Fig 5 19 System Menu I...
Страница 141: ...5 Menu 5 1 Menu structure 137 Fig 5 20 System Menu I...
Страница 254: ...8 Basis of Network Measurement 8 3 Amplifier Parameter Specifications 250...
Страница 257: ...8 Basis of Network Measurement 8 4 Complex Impedance 253...
Страница 366: ...Appendix Appendix 3 Frequency Offset Measurement 362 Fig 3 13 Test of Return Loss of Mixer LO Port...
Страница 373: ...Appendix Appendix 4 Pulse Measurement 369 Fig 4 9 Receiver gain configuration Dialog Box...