![China Electronics Technology Instruments AV3672 Series Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/china-electronics-technology-instruments/av3672-series/av3672-series_user-manual_2601790076.webp)
3 Introduction to Use
3.5 Data Analysis
72
Fig. 3.66 Display of Bandwidth Test Results
3.5.5.3 Shutdown of Bandwidth Test
1) Click
[Analysis] > [Test] > [BW Test]
. The
test
dialog box will appear.
2) Click the
[Bandwidth Test (on/OFF)]
check box and remove the tick to shut down the bandwidth test.
3) Click the
[Bandwidth Value (on/OFF)]
check box and remove the tick to shut down the test bandwidth value
display.
4) Click the
[Bandwidth Marker (on/OFF]]
check box and remove the tick to shut down the bandwidth position
mark display.
5) Click
[OK]
to shut down the bandwidth test.
3.5.6 Equation Editor
3.5.6.1 Overview
In order to facilitate illustration, the following two terms should be defined at first.
Reference trace
: a trace used as data in the equation.
Equation trace
: a current active trace after equation operation.
The user is allowed to enter an algebraic expression in the equation editor. The algebraic expression can be used for
mathematical operation of measurement data. Operation results can be displayed in the data trace form.
Measurement data of the equation trace are the data of one or more channel(s). The mathematical expression
entered by the user is composed of the basic operator, built-in function and parameters. Measurement parameters or
trace data used in the equation are provided by the vector network analyzer. If a calculation equation is entered into
the equation input box and the activation box is ticked, the current active trace will become an equation trace. The
equation trace data are the data after operation, and the equation trace curve can be updated with data changes in a
real-time manner. Take the input equation S21/(1-S11) as an example. The value of each point on the equation
trace is calculated by S21/(1-S11) of the corresponding point. If the trace includes 201 points, the operation will be
done 201 times by the expression, that is, once for each point.
Measurement of a three-port device is not conventional for the analyzer, but can be done through the equation
editor. If the user expects to obtain a logarithmic equation trace, the following expression can be used: S21+S23-
S13. However, the data used in the equation editor are plural data with no format requirements. The user needs to
enter the following equation: S21*S23/S13 as shown in Fig. 3.67. After the equation is entered, Eq=S12*S23/S13
will be displayed on the current active trace of the vector network analyzer, as shown in Fig. 3.68.
Fig. 3.67 Dialog Box of Equation Editor
Содержание AV3672 Series
Страница 1: ...AV3672 Series Vector Network Analyzer User Manual China Electronics Technology Instruments Co Ltd...
Страница 3: ......
Страница 4: ...AV3672 Series Vector Network Analyzer Contents...
Страница 5: ......
Страница 124: ...5 Menu 5 1 Menu structure 120 5 1 2 Track Fig 5 2 Track Menu...
Страница 125: ...5 Menu 5 1 Menu structure 121 5 1 3 Channel Fig 5 3 Channel Menu...
Страница 126: ...5 Menu 5 1 Menu structure 122 5 1 4 Excitation Fig 5 4 Excitation Menu I...
Страница 127: ...5 Menu 5 1 Menu structure 123 Fig 5 5 Excitation Menu II...
Страница 128: ...5 Menu 5 1 Menu structure 124 Fig 5 6 Excitation Menu III...
Страница 129: ...5 Menu 5 1 Menu structure 125 5 1 5 Response Fig 5 7 Response Menu I...
Страница 130: ...5 Menu 5 1 Menu structure 126 Fig 5 8 Repsonse Menu II...
Страница 131: ...5 Menu 5 1 Menu structure 127 Fig 5 9 Response Menu III...
Страница 132: ...5 Menu 5 1 Menu structure 128 Fig 5 10 Response Menu V Fig 5 11 Response IV...
Страница 133: ...5 Menu 5 1 Menu structure 129 5 1 6 Calibration Fig 5 12 Calibration Menu...
Страница 134: ...5 Menu 5 1 Menu structure 130 5 1 7 Marker Fig 5 13 Cursor Menu I...
Страница 135: ...5 Menu 5 1 Menu structure 131 Fig 5 13 Cursor Menu II...
Страница 136: ...5 Menu 5 1 Menu structure 132 Fig 5 15Marker Menu III...
Страница 137: ...5 Menu 5 1 Menu structure 133 5 1 8 Analysis Fig 5 16 Analysis Menu I...
Страница 138: ...5 Menu 5 1 Menu structure 134 Fig 5 17 Analysis Menu II...
Страница 139: ...5 Menu 5 1 Menu structure 135 Fig 5 18 Analysis Menu III...
Страница 140: ...5 Menu 5 1 Menu structure 136 5 1 9 System Fig 5 19 System Menu I...
Страница 141: ...5 Menu 5 1 Menu structure 137 Fig 5 20 System Menu I...
Страница 254: ...8 Basis of Network Measurement 8 3 Amplifier Parameter Specifications 250...
Страница 257: ...8 Basis of Network Measurement 8 4 Complex Impedance 253...
Страница 366: ...Appendix Appendix 3 Frequency Offset Measurement 362 Fig 3 13 Test of Return Loss of Mixer LO Port...
Страница 373: ...Appendix Appendix 4 Pulse Measurement 369 Fig 4 9 Receiver gain configuration Dialog Box...