  5

 

 

 

 

1.4 

運転

 

Operation 

 

運転中に移動させないで下さい。

 

Do not move it during the operation. 

 

停電した時には、電源を切って下さい。復旧時に、けが・装置破損の原因になります。

 

Turn OFF the power when an instantaneous power interruption occurs. 
Otherwise, injury or product damage may be caused when the product recovers. 

 

フィルタを取り外したり、目詰まりや破損した状態で運転すると、

 

ブロア内への異物が混入して、故障の原因となります。  正しくフィルタを取り付けてご使用ください。

 

Operation  without  filter  or  with  a  clogged  and  damaged  filter  may  cause  trouble,  because  foreign 
substances enter the blower. Install the filter properly before operating the machine. 

1.5 

修理・分解・改造

   

Repair, disassembly and modification

 

 

本体を分解・改造しないで下さい。感電・けがの原因になります。内部の点検や修理はお買い上げになった販売店に
連絡して下さい。

 

Do not disassemble or modify the machine. 
Disassembly and modification may cause an electrical shock and injury. 
Contact your dealer for internal inspection and repair. 
 

1.6 

廃棄

 

 

Disposal

 

 

産業廃棄物として適切に処分してください。

 

Dispose of the product properly as industrial wast

 

 

2

 

製品到着時の確認

  Confirmation and Preparation at Arrival 

 

開梱されましたら、各部の不足部品がないかご確認下さい。

 

万一、運送途中での破損・部品不足などがございましたら、すぐにご連絡下さい。

 

After unpacking, make sure that all parts are provided. 

Contact our company immediately if parts are damaged during transportation or not provided. 

 

本体

 

Main Body

 

製品ネームプレートは本体に貼っていますので、ご確認下さい

 

Confirm the nameplate.

 

 

フィルタ(本体にセットされています)

 

Filter

set in the machine

 

 

1

次フィルタ

Primary filter

・・・・・・

  FB-30 

×1

 

 

2

次フィルタ

Secondary filter

・・・・

CHF-3030-50

×1

 

 

排気フィルタ

Exhaust

 

filter

・・・・・

HEP-3030-69

×

 

 

電源ケーブル(付属)とリモートケーブル(別売)

 

Power cable(standard accessory) and Remote cable(option) 

 

 

 

 

 
 
 
 
 
 
 
 

 

 
 

電源ケーブル

Power cable

 

(3m)  ×1 

※  ケーブルは地域によって異なります。 
※  The cable is different in each region. 

 

100-115V 国内 

(Japan) 

本体差し込みプラグ 

/コンセントプラグ 

Power cord plugs 
for main unit side 

and power supply 

socket 

 

200V  国内 

(Japan) 

本体差し込みプラグ 

/コンセントプラグ無 

(切落し) 

Power cord plug 

for main unit side 

and   

without plug

 

(cut 

cable end) for 

power supply 

socket 

 

220-240V  海外

(Other than Japan) 

本体差し込みプラグ 

/コンセントプラグ 

Power cord plugs 
for main unit side 

and power supply 

socket 

 

 

Содержание CBA-1300AT2

Страница 1: ...d this instruction manual thoroughly and handle this CBA Series machine correctly so that you can use it safely for a long time and enjoy its full performance Symbols used in this manual WARNING This...

Страница 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Страница 3: ...8 4 2 AT AT panel 8 4 3 Remote connector 9 4 4 Confirmation before operation 10 4 5 Operation procedure 10 5 Remote Cable Sold Separately 11 5 1 Electrical circuit diagram 11 5 2 Color and signal of e...

Страница 4: ...t outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electri...

Страница 5: ...ternal inspection and repair 1 6 Disposal Dispose of the product properly as industrial wast 2 Confirmation and Preparation at Arrival After unpacking make sure that all parts are provided Contact our...

Страница 6: ...xhaust port AT AT Panel operation panel MAIN POWER switch BOX Fuse Box Remote connector MT 173 8 Remote cable option The remote cable is so designed as to be prevented from falling off Insert it secur...

Страница 7: ...ion flange Detachable flange If th flange diameter needs to be changed to match usage conditions the installed flange can be changed without having to use any tools Replacement flanges are sold separa...

Страница 8: ...4 2 AT AT panel Operating the product with a different power supply may cause a failure 3 ON OFF 30 ON OFF Allow an interval of at least three minutes before turning the equipment ON or OFF If the equ...

Страница 9: ...r decreases due to a factor such as an open front door a clogged exhaust filter or a blocked exhaust duct The lamp turns off when the cause of the problem is corrected Insufficient Airflow Red LED Ale...

Страница 10: ...en it is over 4 0 kPa lower it under 4 0 kPa by adjusting the suction hose Using the suction hose which is too thin and is clogged may cause failure by the load too much Confirm that abnormal sounds s...

Страница 11: ...Temperature correction is not provided Reference example 3 5 6 33 0 1 F Attach a noise limiter Approximately 33 0 1 F to the output terminals Nos 1 2 and 3 When adding inductors such as relays 1 2 3 5...

Страница 12: ...operation The AT panel is disabled while the wires 4 and 8 are short circuited Yellow Change capacity level 0 5 The capacity level can be changed by applying a voltage of 0 to 5V between pins 7 and 8...

Страница 13: ...wire AT ON Lo Hi To change the capacity level using the buttons on the main unit when switching to remote operation check that pin is not shorted circuited then press and hold the ON button on the AT...

Страница 14: ...filter grid frame should be located on the exhaust side Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting inspec...

Страница 15: ...s into the clearance on the left and right sides between the filter case and the filter to remove the filter easily Remove the primary filter from the filter case The paper packing of the primary filt...

Страница 16: ...ion level correct Filter installation status Once month Are the filters installed securely Filter clogged status Suction force check During operation Does the suction hose end offer proper suction for...

Страница 17: ...ing 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operation 30 minutes later Fuses are blown out 6 5 Re...

Страница 18: ...Copyright CHIKO AIRTEC CO LTD 2009 18 8 Electrical Circuit Diagram...

Страница 19: ...onths CBA 1300AT2 FB 30 CHF 3030 50 HEP 3030 69 Note The life above varies depending on the use frequency and suction density Note The contents of this manual are subject to change without prior notic...

Страница 20: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...