CHIEF Vulcan ADU CHH5402 Скачать руководство пользователя страница 4

 

IDENTIFICATION OF THE MAIN PARTS OF THIS MACHINE 

 

 

 

 

 

 

– Compressed air inlet line 

– Chiller power cord connection 

– CAN cable to connect calibrator and lamp controls 

– Pressure gauge (to be set to 1 bar) 

– Air outlet for lamp cooling 

– Lamp power cord connection 

– Generator power cord 

– Generator 

– IR-Lamp 

10 

–Trolley 

11 

– Chiller 

12 

– Water inlet/outlet 

 

STANDARD ACCESSORIES 

The machine comes with the following parts: 

1 Generator ITEM CHH5402 
1 Lamp ITEM CHH5408 and connecting cables. 
 

OPTIONS 

1 Trolley ITEM CHH5480. 
1 Chiller ITEM CHH5480. 
1 Vulcan ADU Instruction Manual. 
1 Control Unit Instruction Manual. 
 
 

TECHNICAL SPECIFICATIONS 

Power supply (three-phase) 

U1N

 

 

Hz 

 

400 

50 

 

400 

60 

 

230 

50 

 

230 

60 

Insulation class 

 

IP rating 

 

IP21 

IP21 

IP21 

IP21 

Chiller cooling system capacity 
 
   

 
 

 
 
 

Generator weight 
 
  Chiller cooling 

lbs 

 

Kg 

57 

 

26 

57 

 

26 

57 

 

26 

57 

 

26 

Lamp weight 
 
  Lamp art. CHH5408 

lbs 

 

Kg 

 

 

 

 

CONNECTION DATA

 

Power cable 
  Length 
  Core section

 

 

mm

 

10 

 

10 

 

10 

 

10 

Required distribution system 
cables / extension cords 
 
  Total L <= 15 m 
  Total L = 30 m

 

 
 
 

mm

mm

 
 

10 

 
 

10 

 
 

10 

 
 

10 

Required line protection 
  Plug 
  Delayed fuses (aM) 

 


 

 

32 
32 

 

 

32 
32 

 

 

32 
32 

 

 

32 
32 

Compressed air minimum pressure 
for rated performance 

 

p1min 

 
 

bar 

psi 

 
 

43.5 

Compressed air maximum pressure  

 
 

p1max 

 
 

bar 

psi 

 
 

130.5 

Compressed air hose min. inside Ø 

 

mm 

 

Minimum compressed air flow 

 

 

l/min 

 

120 

Environmental operating conditions 
 
  Temperature 
  Humidity (non-condensing) 
 

°F 

%/°F 
%/°F 

 

°C 

%/°C 
%/°C 

5-104 

50/107 

90/68 

 

5-40 

50/40 
90/20 

5-104 

50/107 

90/68 

 

5-40 

50/40 
90/20 

5-104 

50/107 

90/68 

 

5-40 

50/40 
90/20 

5-104 

50/107 

90/68 

 

5-40 

50/40 
90/20 

EMISSION DATA

 

Airborne noise 
  Standard cooling 
  Heat exchanger 

 

dB(A) 

 

< 70 

 

< 70 

 

< 70 

 

< 70 

Содержание Vulcan ADU CHH5402

Страница 1: ...TROLLEY ITEM CHH5404 GENERATOR ITEM CHH5402 CHILLER ITEM CHH5403 ITEM CHH5408 ITEM CHH5409 CHIEF Automotive Technologies 996 Industrial Drive Madison IN 47250 Phone 800 445 9262 Fax 866 275 0173 EMAIL salesorders chiefautomotive com DOCUMENT NUMBER IN20784 EDITION 09 29 2016 ...

Страница 2: ...ES 4 OPTIONS 4 TECHNICAL SPECIFICATIONS 4 GENERAL DESCRIPTION 5 SAFETY REQUIREMENTS 5 INSTALLATION 6 ASSEMBLY 6 COOLING SYSTEM 6 ELECTRIC INSTALLATION 6 WORK 7 PRELIMINARY CHECKS 7 PROGRAMMING 7 PROCESS 8 DESCRIPTION 8 MAINTENANCE 9 ORDINARY MAINTENANCE 9 EXTRAORDINARY MAINTENANCE 9 SERVICE AND WARRANTY 10 DISPOSAL 10 ...

Страница 3: ...facturer Any changes even though slight are prohibited because they may compromise machine safety and shall void the machine s EC certification The purpose of this machine consists in repair work at car body shops using infrared heating to remove the panels glued to the inside of a motor vehicle This machine is not suitable for production work CHIEF Automotive Technologies is not responsible for a...

Страница 4: ...IP21 IP21 IP21 Chiller cooling system capacity l Generator weight Chiller cooling lbs Kg 57 26 57 26 57 26 57 26 Lamp weight Lamp art CHH5408 lbs Kg 7 3 7 3 7 3 7 3 CONNECTION DATA Power cable Length Core section m mm2 10 6 10 6 10 6 10 6 Required distribution system cables extension cords Total L 15 m Total L 30 m mm2 mm2 6 10 6 10 6 10 6 10 Required line protection Plug Delayed fuses aM A A 32 3...

Страница 5: ...TALLATION chapter Experienced personnel should carry out the job The machine should be adjusted solely by personnel authorized to do so Since machine adjustments affect operational safety whoever performs said adjustments must possess the required skill Carefully follow the instructions provided in the WORK paragraph It is forbidden for more than one person to work on this machine at a time Prohib...

Страница 6: ...o 3 COOLING SYSTEM In order to cool the machine adequately it is equipped with a chiller that maintains the water in the cooling circuit at a temperature of 68 F This machine cannot be used if connected to a heat exchanger Fill the tank using only a mixture of water and antifreeze liquid for car radiators The antifreeze liquid is necessary for its anti corrosive properties Use only antifreeze liqu...

Страница 7: ...he Vulcan ADU will modulate power so that the object to be heated will not exceed the temperature set on the control unit The profile mode generates a temperature profile that varies over time and contains 5 different temperature values at the most Heating that varies according to a thermal profile is useful to reduce paint drying time or the polymerization time of structural adhesives Drying or a...

Страница 8: ...the process the display shows the temperature values reached by the surface to be heated and the power and set point temperature used To avoid performing low quality work it is advisable to adhere to the following recommendations The glass of the lamp must always be clean When the process is finished power off the machine unplug the electrical plug and shut off the compressed air supply Store the ...

Страница 9: ...ecting cables Replace the power cord if you notice any cracks cuts scrapes etc Make sure the machine is connected to the protective conductor and that the ground wire both inside the power cord and the heating tool connecting cable is not interrupted Periodically check the ground efficiency of the system COOLING CIRCUIT Keep the water level in the chiller within the normal water level Clean the ch...

Страница 10: ...th your fingers Since the bulb should not be touched with your fingers used clean gloves during this operation but if you mistakenly touch the lamps before installing them be sure to clean them using isopropyl alcohol 12 Reconnect the electrical connection cables of the infrared lamp by shortening them as required 13 Refit the latch no 8 14 Refit the two no 5 Allen screws of latch no 8 15 Refit th...

Страница 11: ...11 TECHNICAL DOCUMENTATION DRAWINGS AND TABLES Fig 1 Dimensions ...

Страница 12: ...12 ...

Страница 13: ...13 ...

Страница 14: ...14 ...

Страница 15: ...15 Fig 2 Trolley assembly ...

Страница 16: ...16 Fig 3 Replacing the glass and or lamp ...

Страница 17: ...17 Fig 4 Control unit assembly ...

Страница 18: ...18 ...

Страница 19: ...19 Fig 4 Wiring Diagram ...

Страница 20: ...20 ...

Страница 21: ...21 ...

Страница 22: ...22 Chief Automotive Technologies 999 industrial Drive madison IN 47250 Phone 800 445 9262 Fax 866 275 0173 EMAIL salesorders chiefautomotive com ...

Отзывы: