02/04/2013
PM 2946 7002 09
Page 36 of 39
32.2 Example of protection screens
Protection setting element outlet temperature
Warning alarm high element outlet temperature
32.3 Changing the settings
Starting from the Main screen (the example given describes the protection of the element outlet temperatures).
1.
Press Scroll buttons (12) until <Pr.> followed by a number and the element outlet temperature pictograph is shown.
2.
Press
Enter
button (13).
The warning level for the high temperature warning level <
AL-H
> and the high temperature shut-down level <
Sd-H
>
become visible.
3.
Use Scroll keys (12) to move between the warning level (<
AL
>) and the shut-down level (<
Sd
>).
4.
Press the
Enter
button (13) to modify the value. An optional password may be required.
The value starts blinking.
5.
Use the Scroll buttons (12) to modify the value.
6.
Press the
Enter
button (13) to program the new value.
Note: Programmable settings can only be modified within allowed limits.
1