02/04/2013
PM 2946 7002 09
Page 30 of 39
21.2 Modification
1.
Press
Enter
button (13) to modify the load level (value starts blinking).
A password may be required.
2.
Use Scroll buttons (12) to change the loading pressure.
3.
Press
Enter
button (13) to program the new values or press the
Escape
button (14) to cancel.
22 Modifying the pressure band selection
Starting from the Main screen:
1.
Press Scroll button (12) until <
P.05
> is shown.
2.
Press
Enter
button (13).
The active pressure band 1 (<
Pb.1
>) is shown on the display.
3.
Press
Enter
button (13) to modify the pressure band selection (a password may be required).
The active pressure band <
Pb.1
> starts blinking.
4.
Press Scroll button (12) to modify the active pressure band.
5.
Press
Enter
button (13) to confirm or the
Escape
button (14) to cancel.
23 Calling up/modifying service timer settings
Starting from the Main screen:
1.
Press Scroll button (12) until <
P.06
> is shown.
2.
Press
Enter
button (13): the setting of the service timer is shown in <hrs> (hours) or <x1000 hrs> (hours x 1000).
Example: <4000 hrs> means the timer is set at 4000 running hours.
3.
Press
Enter
button (13) to modify this value (a password may be required).
The value starts blinking.
4.
Use the Scroll buttons (12) to modify the setting.
5.
Press
Enter
button (13) to program the new value.
1