Instruction book
909935AIB
85
9.3 Limits
Limits
Maximum air inlet/ambient temperature
˚C
46
Minimum air inlet/ambient temperature
˚C
0
Maximum cooling air temperature
˚C
46
Minimum cooling air temperature
˚C
0
Maximum working pressure
Refer to the
Compressor
data
section
9.4 Settings of safety valves
Compressor type
Setting
For CPF 300 A compressors with a maximum working pressure of 75, 100,
125, 150 psi
203 psig
9.5 Settings for overload relay and fuses
Overload relay settings of compressors with a motor supply voltage ≤ 690 V
CPF 300 A (CSA-UL, 60 Hz)
Compressor type
Supply voltage (V)
F21 (A)
CPF 300 A
460
258
Fuses
Explanation of fuse types:
• Type2: gL/gG: IEC: 60947-4-1 according:
• IEC60269
• DIN43620
• VDE0636
• CSA: HRC form II/UL: Class K5 according:
• UL248-9
Refer to the data plate of the electrical cabinet for all fuse types and fuse values.
Содержание CPF 300 A-8.6-60
Страница 1: ...People Passion Performance Instruction book ...
Страница 2: ......
Страница 17: ...Instruction book 909935AIB 15 Position of components Ghost view of air cooled CPF 300 A compressor ...
Страница 20: ...Instruction book 18 909935AIB 2 4 Regulating system Flow diagram ...
Страница 61: ...Instruction book 909935AIB 59 Electric cabinet Example of a cubicle for air cooled compressors ...
Страница 94: ......