Instruction book
78
909935AIB
7
Adjustments and servicing procedures
7.1 Air filters
Warning
Stop the compressor, close the air outlet valve, press the emergency stop button and
switch off the voltage. The operator must apply all relevant
Position of air filters
Air filters, CPF 300 A
Step
Action
1
Remove service panel (1) from the compressor.
2
Tilt the brackets (2) of the filter housing cap (3) and remove the filter housing cap.
3
Remove the filter element (4).
4
Fit the new filter element (4).
5
Reinstall the filter housing cap (3) and fasten the brackets (2).
6
Reinstall service panel (1).
7
Reset the service warning after carrying out all service actions in all applicable service
plans. Refer to the service menu section of the ES4000T regulator.