For the machine to maintain the specified
vibration values, always check the following:
Too large a clearance between the working
tool’s shank and the chisel bushing will
generate increased vibrations. To avoid getting
exposed to excessive vibrations, check the
chisel bushing for wear every day.
◆
If the machine has a vibration-absorbing
handle/handles, check that it moves freely (up
and down) and does not jam.
◆
Change damaged parts immediately.
◆
Replace worn components in good time.
◆
Make sure that all the attached and related
equipment, such as hoses, water separators
and oilers are properly maintained.
Periodic maintenance
After each operating period of approximately 150
impact hours or twice a year the machine must be
dismantled and all parts be cleaned and checked.
This work must be performed by authorised staff
who are trained for this task.
Tightening torques
A
B
C
A. Air inlet nipple: 65-75 lbf/ft (88-102 Nm), use
Loctite® 243™ (Loctite is a registered
trademark of Henkel Corporation. 243 is a
trademark of Henkel Corporation.)
B. Nut: First tighten the four nuts diagonally with a
torque of 15 lbf/ft (20 Nm). Then tighten the
nuts in sequence using the same torque. This is
to allow the nylon bumper to set properly.
C. Nylon bumper
Troubleshooting
If the pneumatic machine does not start, has low
power or uneven performance, check the following
points.
◆
Check that the working tool being used has the
correct shank dimension.
◆
Check that the pneumatic machine is getting
the correct amount of lubricant. Too much
lubrication can cause starting problems, low
power or uneven performance.
◆
Check that the compressed air system supplies
the machine with sufficient air pressure to give
full power.
◆
Check that the dimension and length of the air
hose are according to the recommendations.
See “Installation”.
◆
If there is a risk of freezing, check that the
machine's exhaust ports are not blocked.
◆
If the machine function is still not satisfactory
after this procedure, contact an authorised
service workshop.
Storage
•
Clean the machine properly before storage, in
order to avoid hazardous substances. See
“Dust and fume hazard”
•
Pour approximately
1
⁄
2
oz (5 cl) of oil directly into
the air inlet nipple, connect the machine to the
compressed air supply and start it for a few
seconds.
•
Always store the machine in a dry place.
Disposal
A used machine must be treated and disposed of
in such a way that the greatest possible portion of
the material can be recycled and any negative
influence on the environment is kept as low as
possible, and in respect to local restrictions.
CP 0016, 4130, 4131, 4132, 4134
Safety and operating instructions
9800 0616 71 |
Original instructions
19
Содержание CP 4131
Страница 4: ......
Страница 42: ...58 58 59 60 2006 42 60 CP 0016 4130 4131 4132 4134 42 9800 0616 71...
Страница 44: ...CP 0016 4130 4131 4132 4134 44 9800 0616 71...
Страница 45: ...CP 0016 4130 4131 4132 4134 9800 0616 71 45...
Страница 46: ...CP 0016 4130 4131 4132 4134 46 9800 0616 71...
Страница 47: ...CP 0016 4130 4131 4132 4134 9800 0616 71 47...
Страница 48: ...tinnitus CP 0016 4130 4131 4132 4134 48 9800 0616 71...
Страница 49: ...CP 0016 4130 4131 4132 4134 9800 0616 71 49...
Страница 55: ...A B C D CP 0016 CP4130 CP4131 D D C D B CP 4132 CP 4134 A A CP 0016 4130 4131 4132 4134 9800 0616 71 55...
Страница 57: ...1 2 oz 5 cl CP 0016 4130 4131 4132 4134 9800 0616 71 57...
Страница 100: ...116 116 117 118 2006 42 EC 118 CP 0016 4130 4131 4132 4134 100 9800 0616 71...
Страница 102: ...CP 0016 4130 4131 4132 4134 102 9800 0616 71...
Страница 103: ...CP 0016 4130 4131 4132 4134 9800 0616 71 103...
Страница 104: ...CP 0016 4130 4131 4132 4134 104 9800 0616 71...
Страница 105: ...CP 0016 4130 4131 4132 4134 9800 0616 71 105...
Страница 106: ...CP 0016 4130 4131 4132 4134 106 9800 0616 71...
Страница 107: ...CP 0016 4130 4131 4132 4134 9800 0616 71 107...
Страница 113: ...A B C D CP0016 CP4130 CP4131 D D A C D B CP 4132 CP 4134 A CP 0016 4130 4131 4132 4134 9800 0616 71 113...
Страница 115: ...C 1 2 5 CP 0016 4130 4131 4132 4134 9800 0616 71 115...
Страница 174: ......
Страница 194: ......
Страница 214: ......
Страница 234: ......
Страница 293: ......
Страница 294: ......
Страница 295: ......
Страница 296: ...2017 06 30 No 9800 0616 71 Construction Tools PC AB...