When taking a break
♦
During all breaks you must place the machine in
such a way that there is no risk for it to be
unintentionally started. Make sure to place the
machine on the ground, so that it can not fall.
♦
In the event of a longer break or when leaving the
workplace: Switch off the power supply and then
bleed the machine by activating the start and stop
device.
Maintenance
Regular maintenance is a basic requirement for the
continued safe and efficient use of the machine.
Follow the maintenance instructions carefully.
♦
Before starting maintenance on the machine,
clean it in order to avoid exposure to hazardous
substances. See “Dust and fume hazards”
♦
Use only authorised parts. Any damage or
malfunction caused by the use of unauthorised
parts is not covered by warranty or product
liability.
♦
When cleaning mechanical parts with solvent,
comply with appropriate health and safety
regulations and ensure there is satisfactory
ventilation.
♦
For major service to the machine, contact your
nearest authorised workshop.
♦
After each service, check that the machine's
vibration level is normal. If not, contact your
nearest authorised workshop.
Every day
Before undertaking any maintenance on pneumatic
machines, always switch off the air supply and bleed
the machine by turning the start and stop device.
Then disconnect the air hose from the machine.
♦
Clean and inspect the machine and its functions
each day before the work commences.
♦
Never submerge the exhaust in water when
cleaning.
♦
Conduct a general inspection for leaks and
damage.
♦
Check that the air inlet nipple is tightened and
that the claw coupling is free from damage.
♦
Change damaged parts immediately.
♦
Replace worn components in good time.
♦
Make sure that all the attached and related
equipment, such as hoses and water separators
are properly maintained.
Periodic maintenance
With regular use or twice a year the machine must
be dismantled and all parts be cleaned and checked.
This work must be performed by authorised staff,
trained for this task.
Tightening torques
A.
Nut - bearing lock, tighten snug against and
then
1
⁄
8
turn more, use Loctite® 271™
B.
Cap - end, 160-180 lbf/ft (217-244 Nm), use
anti-seize lubrication on threads.
C.
Nipple - hose, 80-100 lbf/ft (108-136).
D.
Screw, use Loctite® 271™.
E.
Coupling - pipe, 100-120 lbf/ft (136-163 Nm).
F.
Nipple - hose, 100-120 lbf/ft (136-163 Nm).
G.
Nipple, 100-120 lbf/ft (136-163 Nm).
9800 0618 90 | Original instructions
14
CP 2190
Safety and operating instructions
www.CrowderSupply.com • Toll Free: 888-883-5144
Crowder
Supply
Co.,
Inc.
• 8495
Roslyn
St.,
Commerce
City,
CO
80022
• Toll
Free:
888-883-5144
• www.CrowderSupply.com