King Edge
Troubleshooting
6-15
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
ISSUE
POSSIBLE CAUSE
SOLUTION
Station Carriage Does Not
Clamp and Transport Flatwork
1. CB11 is tripped, CON4 is
bad, CB8 is tripped, T8 is
bad, or CR5 is bad.
Reset and/or test and replace com-
ponent as necessary.
•
2. Sensor PE31 (Station 1) or
PE35 (Station 2) not func-
tioning properly.
Check. For more information within
this chapter, refer to
Sensor Func-
tion
section,
Sensor Function
Issue
issue.
•
3. Carriage down proximity
sensor PX32 (Station 1)
or PX36 (Station 2) not
functioning.
Check. For more information within
this chapter, refer to
Sensor Func-
tion
section,
Proximity Sensor Not
Working
issue.
•
4. Carriage clamp air cylinder
malfunction.
Check. For more information within
this chapter, refer to
Compressed
Air System
section.
•
5. Solenoid fuse on circuit
board is burned out.
Check/replace fuse on MPC1
prefeeder board.
•
6.Carriage drive belt slipping
or broken.
Check condition/tension of belt. Re-
pair/retension or replace as neces-
sary.
•
7. Carriage drive motor/in-
verter problem.
Check. Repair/replace as necessary.
•
Station Carriage Continually
Goes Up and Down
1. Photosensor or connector
is bad.
Check PE31, PE35 as appropriate.
Repair/replace as necessary.
•
Flatwork Stops at the Inlet
Transfer Pickup Clamps
1. Carriage up proximity
sensor PX33 (Station 1)
or PX37 (Station 2) not
functioning.
Check. For more information within
this chapter, refer to
Sensor Func-
tion
section,
Proximity Sensor Not
Working
issue.
•
2. Inlet transfer pickup
proximity sensor PX9 not
functioning.
Check. For more information within
this chapter, refer to
Sensor Func-
tion
section,
Proximity Sensor Not
Working
issue.
•
3. Transfer rodless air cylin-
der malfunction.
Check. For more information within
this chapter, refer to
Compressed
Air System
section.
•
4. Solenoid fuse on circuit
board is burned out.
Check/replace fuse on MPC1
prefeeder board.
•
6.5 Prefeed/Inlet Section
Содержание King Edge
Страница 1: ...KING EDGETM Large Piece Spreader Feeder INSTRUCTION MANUAL...
Страница 66: ......
Страница 122: ......
Страница 182: ......
Страница 183: ...King Edge 3024 016c C 1 King Edge Spreader Feeder CHI PANEL OPERATION KING EDGE TYPE 00 04 PROGRAMS...
Страница 200: ......
Страница 202: ......
Страница 207: ...5 King Edge PL 3038 008M This Page Blank on Purpose...
Страница 218: ...16 PL 3038 008M King Edge Drive Detail Left 23 18 5 17 20 1 3 19 2 25 24 22 21 4 15 7 6 16 16 8 9 10 14 13 12 11...
Страница 240: ...38 PL 3038 008M King Edge This Page Left Blank On Purpose...
Страница 260: ...2...
Страница 262: ...4...
Страница 264: ...6...
Страница 266: ...8 C...
Страница 268: ...10...
Страница 270: ...12...
Страница 272: ...14...
Страница 274: ...16...
Страница 276: ...18...
Страница 277: ...19...
Страница 278: ...20...
Страница 280: ...22...
Страница 281: ...23...
Страница 282: ...24...
Страница 284: ...Skyline S1 S20 Installation...
Страница 285: ......
Страница 286: ...Skyline S1 S20 Installation...
Страница 288: ......
Страница 290: ......