Troubleshooting
King Edge
6-12
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
ISSUE
POSSIBLE CAUSE
SOLUTION
(continued from previous page)
Unit Does Not Start
Message reads:
CIRCUIT BREAKER TRIPPED
SERVICE OR CLEAR FAULT
or
INVERTER/MOTOR OVERLOAD
SERVICE OR CLEAR FAULT
3. Inverter needs to be reset.
Reset the inverter:
Turn the power OFF at the main
disconnect switch.
Wait one minute.
Turn power ON at the main discon-
nect switch.
If the fault repeats:
Input voltage is too high or low. The
voltage should be between 185v
and 245v.
There is a motor over current.
Check for excessive physical load
on the motor.
Open circuit between an inverter
and its motor.
An inverter-powered motor is bad.
There is an overbraking problem.
Contact the Chicago Dryer factory
Service Department.
•
-
-
-
•
-
-
-
-
-
Florescent Lamp Does Not
Light
1. Bulb is burn out.
Check/replace as necessary.
•
2. Fixture/ballast is bad.
Check/replace components as nec-
essary.
•
3. CB 9 is tripped.
Check/reset as necessary.
•
4. T9 is back.
Check/replace as necessary.
•
Unit Starts, Then Shuts Down
(continued on next page)
1. Control latching circuit
(hold) is defective.
(continued on next page)
Perform the following check:
Press a red safety STOP button or
open an interlock switch.
Press START and check for mes-
sage indicating open safety switch
location.
See if message stays displayed or
disappears after a few seconds.
If message disappears after a few
seconds:
Check wiring connections between
PB7 (start) and their associated con-
tacts, PSC1, MPC1, OC1 and CR1.
Check PSC1/MPC1 and OC1. Re-
place if necessary or consult factory.
Check CR1. Replace if necessary.
•
-
-
-
•
-
-
-
Содержание King Edge
Страница 1: ...KING EDGETM Large Piece Spreader Feeder INSTRUCTION MANUAL...
Страница 66: ......
Страница 122: ......
Страница 182: ......
Страница 183: ...King Edge 3024 016c C 1 King Edge Spreader Feeder CHI PANEL OPERATION KING EDGE TYPE 00 04 PROGRAMS...
Страница 200: ......
Страница 202: ......
Страница 207: ...5 King Edge PL 3038 008M This Page Blank on Purpose...
Страница 218: ...16 PL 3038 008M King Edge Drive Detail Left 23 18 5 17 20 1 3 19 2 25 24 22 21 4 15 7 6 16 16 8 9 10 14 13 12 11...
Страница 240: ...38 PL 3038 008M King Edge This Page Left Blank On Purpose...
Страница 260: ...2...
Страница 262: ...4...
Страница 264: ...6...
Страница 266: ...8 C...
Страница 268: ...10...
Страница 270: ...12...
Страница 272: ...14...
Страница 274: ...16...
Страница 276: ...18...
Страница 277: ...19...
Страница 278: ...20...
Страница 280: ...22...
Страница 281: ...23...
Страница 282: ...24...
Страница 284: ...Skyline S1 S20 Installation...
Страница 285: ......
Страница 286: ...Skyline S1 S20 Installation...
Страница 288: ......
Страница 290: ......