S e c . 6Y
P a g e 40
STARTING SYSTEM
}
»
\
Figure 1— Starter Autom atic D isenga ge m en t an d Lock-Out (Series TG50) (Typical)
STARTER AU TO M ATIC
DISEN G AG EM EN T A N D LOCK-OUT
Inform ation applicable to the Starter Automatic
D isengagem ent and Lock-Out sy ste m u sed on S e r ie s
C G /SG /T G -50 rem a in s the sam e as covered under
“ Starter A utom atic D isengagem ent and Lock-Out”
in ENGINE ELECTRICAL (SEC. 6Y) in S erv ice
Manual S T -331-71 excep t as follow s:
NOTE: A typ ical sy ste m u sed on S e r ie s TG-
50 is shown in figu re 1, and a typ ical sy ste m used
on S e r ie s C G /SG -50 i s shown in figu re 2.
On som e v e h ic le s equipped with the autom atic
tr a n sm issio n , the sta r te r m agnetic sw itch operat
ing c o il is en ergized through the com bination neu
tr a l safety and back-up lamp sw itch when the tr a n s
m issio n sh ift le v e r is in neutral p osition.
When tra n sm issio n shift le v e r is in neutral
p o sitio n and engine control sw itch is placed in
’'START" p osition , current from the battery w ill
en erg ize the sta r te r m agnetic sw itch operating
c o il through the com bination neutral start and
back-up lam p sw itch, thus com pleting circu it to the
startin g m otor. When tr a n sm issio n is shifted out
of neutral, feed circu it to sta r te r m agnetic sw itch
operating co il is broken, thus preventing sta rter
engagem ent.
Figure 2 — Starter Autom atic D ise n ga ge m e n t an d Lock-Out
(Series C G / S G 5 0 ) (Typical)
f
€ > j- * 0 0 B L K — ||l> FRAME
—
—
(AMMETER. SH UNT)'
STARTER ASM.
FRAME
TO AMMETER AND VOLTMETER
110 BLK. (AMMETER SHUNT)'
STARTERASM.
TRANSISTORIZED VOLTAGE REGULATOR
GENE RA TO R
VOLTAGE REGULATOR
GENERATOR
16 BLK
---------
16
BLK------------------
TO ACCESSORY BUS BAR
■16 BLK-
STARTER MAG. SW.
■H
hQQQr-O-
STARTER MAG. SW .
CONTROL
SW.
STARTER CONTROL
RELAY
STARTER CONTROL
RELAY
I6BLK
I6 B L K '
CONTROL SW.
---14 PIN K ---
TRANSMISSION
CONTROL
■12 PU RPLE'
•12 PURPLE'
WITH M ECH ANICAL TRAN SM ISSIO N
WITH AUTOMATIC TRANSM ISSIO N