For example, Dual Engine support in one unit can be provided by selecting PGNs 127488,
127489, 127508, and 127505 with instance 0 (PORT engine) and 1 (Starboard Engine)
Alternately, a 12 function Tank monitoring system can be created by selecting PGN 127505
and assigning a separate instance (0-11) to each of the 12 sensor inputs.
PGN 127488 Engine Parameters Rapid
Fields Supported
Range
Resolution
Units
TX
RX
RPM**
0-10000
25
RPM
X
X
BOOST
0-237 psi
0.92 psi
Pascals
X
X
TRIM
0
–
100%
0.4%
Percent
X
X
* Default Field
–
must choose default field when configuring PGN
PGN 127489 Engine Parameters Dynamic
Fields Supported
Range
Resolution
Units
TX
RX
Engine Temperature**
-20F
–
278F
1.5F
Kelvin
X
X
OIL Pressure
0 - 237 psi
0.92 psi
Pascals
X
X
Oil Temperature
-18F
–
718F
2.9F
Kelvin
X
X
Alternator Volts
0 - 40V
0.16V
Volts
X
X
Engine Hours
1193046 hours 1 sec
Seconds
X
X
Coolant Pressure
0-471 psi
1.8 psi
Pascals
X
X
Fuel Pressure
0
–
74 psi
0.3 psi
Pascals
X
X
Fuel Rate
0
–
1700 GPH 0.1 GPH
L/sec
X
X
** Default Field
–
must choose default field when configuring PGN
PGN 127508 Battery Status
Fields Supported
Range
Resolution
Units
TX
RX
Battery Volts **
0 - 40V
0.16V
Volts
X
X
Battery Current
0
–
410 Amps 1.6 Amps
Amps
X
X
Battery Temperature
-20F
–
278F
1.5F
Kelvin
X
X
** Default Field
–
must choose default field when configuring PGN