background image

 

2

 

 
 

- HCL  

1.

 

Bioloog Ian 

2.

 

Kerel met duikbril 

 

Installation instruction mini BLC 4DI 

V8.0 / 06-04-2020 

www.chess.nl 

Application 

Refer to the mini BLC 4DI product sheet (see chess.nl) for the product specifications and 
environmental conditions.

 

Installation 

 

Install the mini BLC 4DI in the direct neighborhood of other Mymesh products. 

 

Mount the mini BLC 4DI with 2x M3 screw/bolt (76 mm distance). 

 

Use maximal 1.5 mm2 wiring for all connections. Push the wires completely into the terminal 
block. Use wire end sleeves when using flexible wires. 

 

Connect the 230VAC supply voltage to the mini BLC 4DI. Connect one up to four contact 
inputs and the common GND to external voltage free contacts (see wiring diagram below).  

 

One mini BLC 4DI controls one luminaire. 

mini BLC 4DI + voltage free contacts: 

 

 

Antenna mounting 

 

Connect the supplied antenna to the antenna connector. 

 

The antenna is used for wireless communication with other Mymesh products. Operation of 
the antenna should not be disrupted. 

o

 

Do 

not

 mount the antenna inside a metal housing, flat on a metal surface or directly 

next to a large metal object. 

o

 

Some glass and plastic materials such as safety glass, tinted glass and double glass 
influence the operation of an antenna.  

o

 

Use a plastic, polycarbonate or fiberglass housing 

without

 carbon 

o

 

Mount the antenna 

outside

 the housing/cabinet if necessary. Ensure that the 

thickened part at the end of the antenna is positioned 

outside

 a housing plus 1.5cm of 

the antenna cable. Use a grommet for protection of the antenna cable. 

 

 

230VAC

1
2

3

4

5004.

Содержание Mymesh mini BLC 4DI

Страница 1: ...on must be in conformance with the national legislation and relevant standards The mains connection of the mini BLC 4DI must be provided with a fuse or circuit breaker Disconnect power at the source before installation inspection or removal Do not use the mini BLC 4DI if it is damaged The mini BLC 4DI is suitable for use at indoor locations IP20 protection class Mount the mini BLC 4DI in an IP66 h...

Страница 2: ...e contacts see wiring diagram below One mini BLC 4DI controls one luminaire mini BLC 4DI voltage free contacts Antenna mounting Connect the supplied antenna to the antenna connector The antenna is used for wireless communication with other Mymesh products Operation of the antenna should not be disrupted o Do not mount the antenna inside a metal housing flat on a metal surface or directly next to a...

Страница 3: ... 20 30 meters in complex buildings with a lot of damping through walls partitions and ceilings o 50 to 75 antenna range is acceptable for situations where luminaires are installed in close proximity approximately 10 20 meters in buildings with limited attenuation due to partitions o 25 to 50 antenna range is acceptable for situations where luminaires are installed in an open space in close proximi...

Страница 4: ...a in a metal housing junction box Figure 5 Freely place the antenna in a plastic junction box housing not against plastic Figure 3 Route the thickened part of the antenna completely through the metal housing cabinet Figure 2 Route the thickened part of the antenna completely through the metal housing cabinet plus 1 5cm of the antenna cable ...

Страница 5: ...complies with the European directives and relevant standards for low voltage EMC RED REACH and RoHS The mini BLC 4DI contains a 2 4 Ghz radio The applied frequency of the radio is within the band 2 401 2 483 GHz and the maximum transmit power is 4 dBm Hereby Chess Wise declares that the radio equipment type mini BLC 4DI is in compliance with Directive 2014 53 EU The full text of the EU declaration...

Отзывы: