50
ADJUSTMENT OF THE LIMIT SWITCHES
SETTING IN MODE 1 (manual)
The motors have an electronic limit switch system with an encoder. This system ensures
great reliability and precision in keeping the positions. Limit switch regulation is performed
simply with the remote control. During setting, the motor moves only as long as the up or
down button is pressed, stopping when the button is released. At the end of setting, press
either the up or down button briefly to move the motor.
The adjustments of the limit switches can be done in different modes depending on
whether the rolling shutter is equipped with lockdown hangers or physical stops.
In this mode it doesn’t matter whether or not the rolling shutter has got physical stops in
the opening position and the lockdown hangers in the closing position. It is possible to
choose whether to set the upper limit or the lower limit first. The correct rotation direction
will only be identified after the first position is set so it is sometimes necessary to use the
“up” or “down” button.
SETTING THE FIRST REMOTE CONTROL
This operation can only be performed when the motor is new, or after a total delete of
the memory.
T1: First remote control to be set
During this step, power up only one motor at time!
T1
T1
T1 (2 sec)
Every time you connect the power supply to the motor, you have 3 hours to store the
first remote control. After this time, the ability to store the remote control is disabled.
To reset the timer of the function you have to disconnect and reconnect the power
supply to the motor.
AUTOMATIC DISABLING OF THE FIRST
REMOTE CONTROL SETTING FUNCTION
REMO
TE CONTROL PROGR.
E N G L I S H
+
A
B
B
B