CONFIGURATIONS

Favorite positions

Parameter 

Number

Size

Parameter 

Name

Default 

Value

Description

2

1

ON_ 

FAVORITE_ 

LEVEL

80

The On level reached when the Up 
Button received a double click.

 Parameters Values                                         Min: 50                        Max: 99

Value

Description

50-99

50-99% opening level (99% correspond to completely open)

Parameter 

Number

Size

Parameter 

Name

Default 

Value

Description

3

1

ON_ 

FAVORITE_ 

LEVEL

20

The Off level reached when the Down 
Button received a double click. 

 Parameters Values                                        Min: 0                        Max: 49

Value

Description

0-49

0-49% opening level (0 correspond to completely closed)

The system can set two favorite positions: one for the upward movements (opening 
movements) 

Favorite level for ON position

, the other for the downward movements 

(closing movements) 

Favorite level for OFF position

.

E

NG

L

IS

H

Содержание A510078

Страница 1: ...D R A F T ISTRUZIONI INSTRUCTIONS EINSTELLANLEITUNGEN INSTRUCTIONS INSTRUCCIONES Actuator for motors with standard connection EN A510078 META WIRED MOTOR CONTROLLER 7 ...

Страница 2: ......

Страница 3: ...elevant Union harmonisation legislation Directive 2014 53 EU Directive 2011 65 EU The full text of the EU declaration of conformity is available upon request at the following website www cherubini it Failure to comply with these instructions annuls CHERUBINI s responsibilities and guarantee The crossed out wheelie bin symbol indicates that the product must be collected separately from other waste ...

Страница 4: ...is equipped with contact protection technology Zero Crossing which reduces the electrical stress on the relay contacts and ensures a longer life The open closed switching of the device always occur when the instantaneous value of voltage is 0 It operates in any Z Wave network with other Z Wave Z Wave Plus certified devices and controllers from any other manufacturer As a constantly powered node th...

Страница 5: ...ms in compliance with safety requirements set out by the regulations in force DANGER The device must be connected with a voltage of 230 VAC before carrying out any operation please make sure the power main switch is in OFF position DANGER Any procedure requiring the use of the Integrated Button is related only to the installation phase and is to be considered a service procedure that must be perfo...

Страница 6: ...LECTRICAL CONNECTIONS DIAGRAM 6 WARNING The power line must be opportunely protected from short circuits and excess load due to a potential motor malfunction Power Supply 1 Null 6 Line Commands Switch 2 3 Motor terminals 4 5 E N G L I S H 1 2 3 4 5 6 M N L 1 Neutral 6 Phase 4 5 Motor terminals 2 3 Commands switch ...

Страница 7: ...shows the device s status during installation Solid RED the device is not included in any network Solid BLUE the device is Offline setup mode Blink BLUE calibration 4 GREEN blinks then OFF the device has been just added to a Z WaveTM network in S2 Authenticate Mode 4 BLUE blinks then OFF the device has been just added to a Z WaveTM network in S2 Unauthenticated Mode 4 RED blinks then OFF the devic...

Страница 8: ... RED The adding of a device is executed by activating the adding procedure in the inclusion section of the controller interface and then executing 1 or 3 click on the integrated button the device is set in Learn Mode As soon as the inclusion procedure initiates the LED indicator starts a sequence of GREEN BLUE blinks The device is included in the network when the LED status is OFF and the intervie...

Страница 9: ...ted devices META Serie 7 devices can be added into a Z WaveTM network by scanning the Z WaveTM QR Code present on the product with a controller providing SmartStart inclusion No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity The SmartStart QR and the full DSK string code can be found on the back of th...

Страница 10: ...2 x INDICATOR 2 X ASSOCIATION 2 x MULTI_CHANNEL_ASSOCIATION 3 x ASSOCIATION_GRP_INFO 2 x TRANSPORT_SERVICE 1 x VERSION 2 x MANUFACTURER_SPECIFIC 2 x POWERLEVEL 1 x CONFIGURATION 4 x SECURITY_2 1 x SUPERVISION 1 x FIRMWARE_UPDATE_MD 5 x WINDOW_COVERING 1 x MULTILEVEL 4 x NOTIFICATION 9 x E N G L I S H ...

Страница 11: ...by the indicator will be RED if the device is included without Security BLUE if the device is included in S2 Unauthenticated Mode GREEN if the device is already included in S2 Authenticated Mode Basic Command received Commando Mappato multilevel Switch Basic Set 0xFF Multilevel Switch 0xFF Basic Set 0x00 Multilevel Switch 0x00 Basic Set 1 0x63 Multilevel Switch 1 0x63 Basic GET Basic Report Curren...

Страница 12: ...e event applies only if there has been a previous Hold Down event E N G L I S H The CONTROL ACTIONS are EVENTS executed on EXTERNAL SWITCHES connected to the UP and DOWN terminal of the device which can be Clicks Hold Down and Up Device status ON OFF STOP Open Close Stop refers to the fact that the motor is rotating towards the direction Open Close or it is stopped Result of Control Actions Holdin...

Страница 13: ...or Controller 7 can control other devices like other relays or dimmers The device supports 1 association group which supports the association of up to 8 devices nodes Group ID Group Name N of max nodes sup ported in the group Description Command sent 1 Lifeline 8 Lifeline Group Nodes belonging to this group will receive notifica tions about device reset changes related to the shutter status and In...

Страница 14: ...utton After the reset is completed the device will reboot and a RED solid led is showed Please use this procedure only when the network primary controller is missing or otherwise inoperable INFO If the reset is performed while the device is still part of a network it notifies the other devices that it has been removed Device Reset Locally Notification WARNING The system will be rebooted at the end...

Страница 15: ... This configuration will apply only if the calibration is completed Set ON OFF favorite Level The current level will be set as ON_ FAVORITE_LEVEL if the current level is greater than 49 or will be set to OFF_FAVORITE_LEVEL if the current level is smaller than 50 If you want to set both ON and Off favorite Level you have to carry on this setup two times One time for the ON position by moving the mo...

Страница 16: ...ely open Parameter Number Size Parameter Name Default Value Description 3 1 ON_ FAVORITE_ LEVEL 20 The Off level reached when the Down Button received a double click Parameters Values Min 0 Max 49 Value Description 0 49 0 49 opening level 0 correspond to completely closed The system can set two favorite positions one for the upward movements opening movements Favorite level for ON position the oth...

Страница 17: ...2 to the appropriate time in millisecond During the calibration the LED indicator blinks repeatedly in BLUE Parameter Number Size Parameter Name Default Value Description 20 1 CALIBRA TION_COM PLETE 0 Define if the device has been calibrated Parameters Values Min 0 Max 1 Value Description 0 TO_BE_DONE Calibration to be done 1 DONE Calibration has been done Parameter Number Size Parameter Name Defa...

Страница 18: ...meter Number Size Parameter Name Default Value Description 23 4 INVERTION_ TIMEOUT 1000 Time in thousandth of a second after which the movement direction can be changed Parameters Values Min 1000 Max 10 000 Value Description 1000 10 000 Time expressed in thousandths of a second Parameter Number Size Parameter Name Default Value Description 24 4 LIMIT_ SWITCH_ TIMEOUT 3000 Time in thousandth of a s...

Страница 19: ...Description 37 4 REPORT_ FREQUENCY 5 Time in seconds after which the new po sition report is sent if the target position is not reached When the target position has been reached a final position report is sent Parameters Values Min 1 Max 100 Value Description 1 100 Time expressed in second Parameter Number Size Parameter Name Default Value Description 38 4 SEND_ MULTILE VEL_ REPORT 0 Define if the...

Страница 20: ...version If after the calibration the movement of the motor is opposite to the command issue goes up if it is required to go down and vice versa the movement can be inverted This parameter can be set also using the offline setup mode Parameters Values Min 0 Max 1 Value Description 0 NOT_INVERTED 1 INVERTED E N G L I S H ...

Страница 21: ......

Страница 22: ...as Barbet 165 Impasse Ampère 30600 Vauvert France Tél 33 0 466 77 88 58 Fax 33 0 466 77 92 32 info cherubini fr www cherubini fr CHERUBINI Iberia S L Avda Unión Europea 11 H Apdo 283 P I El Castillo 03630 Sax Alicante Spain Tel 34 0 966 967 504 Fax 34 0 966 967 505 info cherubini es www cherubini es CHERUBINI S p A Via Adige 55 25081 Bedizzole BS Italy Tel 39 030 6872 039 Fax 39 030 6872 040 info ...

Отзывы: