RADIANTE 846 2V
STANDARD INSTALLATION
LEGEND
Firebox Dimension
Exact Dimension
Minimum Dimension
Air Intake
Air Outlet
FIREPLACE
CONSTRUCTION STEP 1
FIREPLACE
CONSTRUCTION STEP 2
SECTION ‘A’
A
842
1375
514
Flue
Lintel
Firebox
Air Grille
Air Grille
Firerock Insulation
Hearth
Hearth
Hearth
Fireplace base
500
1800
610
See note [3]
50
860
842
50
634
200
500
Hearth
To ceiling height
Cutaway
showing
lintel
Air grilles to be
either large front
as shown, or sides
x2 (dotted).
50
50
634
Air intake grilles
Air intake
grille
Air intake
grille
IMPORTANT:
NO BRICKWORK TO
BE COMMENCED
UNTIL FIREBOX IS
PLACED IN POSITION
NOTES:
[1]
Air intake grilles minimum air flow area required
= 180cm
2
each side.
[2]
Air outlet grilles minimum air flow area = 240cm
2
each side
and 480cm
2
if one grille is used.
[3]
Hearth height dimensions optional (Refer to Technical Data
& Installation Instructions)
[4]
All dimensions in millimetres.
[5]
Heater can be left freestanding.
[6]
Do not scale from these diagrams
[7]
Air transfer kits mandatory for exempt units to comply to
AS/NZ 4012/4013:2014. Fan optional depending
on duct length. ( Refer to Technical Data & Installation
Instructions )
A
u
g
u
st
2
0
1
8
Cheminees Philippe’s policy is one of continuous development. We reserve the right to change sizes and specifications without notice.
430 Johnston St., Abbotsford, Victoria 3067 Phone: 03 9417 3315
e-mail: [email protected] www.chemphilaust.com.au
Air Transfer Kit
Ceiling
Brick Masonry
OR
50mm Skamotec 225
*
*
*
*
= 30mm air gap
to combustibles
when using
Skamotec