Quick Start Guide: E10 2.0 RF/RFID Pedestals
Page 7 of 9
Complete Wiring
The detailed procedure below has floor cut and ferrite core installation details
that apply to all E10 2.0 installations. For RF-EAS system setup, refer to the
Evolve manual
(CKP P/N 7994249)
or Quick Start Guide
(CKP P/N 10077599)
.
Procedure
1. Make the aisle floor cuts to accept all cables for Dual RF/RFID system. For the
single aisle layout, shown below with the minimum cables for PRI to SEC and
RFID support, there will be five (5) individual cables in the aisle:
• 2 RFID Coax Cables
• 1 RFID Interpedestal Communication cable (LED + COMMs)
• 1 RF-EAS Coax Cable
• 1 RF-EAS Sync Cable
Figure 8:
Single Aisle floor plan
Note: The number will vary in other aisles (where the 8C modular cable will link between primaries, for example).
Note: RF-EAS may use the same network (refer to Step 6 below), depending on if Evolve will have its own Ethernet uplink.
2. Route Cat 5e from client network connection(s), where each reader can have an
independent uplink, or readers can be chained and only one unit makes a physical
TCP/IP connection (Network Site design). Wait to make live Ethernet connection
with customer network; during setup, typically a unique IP address is assigned to
each reader; and the customer IT plan will determine what settings to apply.