Checkpoint Systems, Inc.
– Field Service Installation Document – CKP P/N
#######
Page 8 of 9
3. From this pedestal’s reader, connect
from the Interped OUT Port using an
interpedestal network cable (shielded
Cat 5e from RFID installation/cable
kit (cable is CKP P/N 7206088 - and
the kit is CKP P/N 10083615). Apply
a 10cm ferrite core with 2 turns.
4. Route Cat5 and coax cables to next
pedestal (if not already). For either
PP or PN type units, this connection
will carries RFID lights and sound,
as well as RFID Network signal.
Figure 9:
InterPED wiring
5. Connect at the InterPED IN Port and apply a 10cm ferrite core with 2 turns.
6. At last pedestal, connect from NETWORK Port to the Evolve board for TCP/IP
network sharing.
7. Connect the RF-EAS Sync cable (shown with ferrite core already applied). Apply
10cm ferrite core.
8. Connect the RFID Coax cable pair (this can be done at any time, before power up).
• RX4 to RX4 array keeping the labels accurate for future reference.
• RX3 to RX3.
9. Connect PSU to the system. First use Voltmeter to
id - polarity of DC power cord. C to
Pin1 of connector and - to Pin 3 as shown. Insert plug
into power receptacle, then tighten the screws until
secure. If needed, PSUs can be “daisy-chained.”
Complete RFID Alarm LED Wiring
Lamp 1, Lamp 2 and Lamp Center all share the same pinout. Any lights for RFID to be supported, terminate the 1
pin connector and plug in at the side of Reader chassis.
Optional: External Sounder Connection
Another sounder (besides the one inside the RFID reader) can be equipped. Install the unit inside the pedestal as
recommended, then wire with same pin-out above.
Pin #
2-Pin Euro Connector
Wire Color (Polarity)
1
Right
Red (+)
2
Left
Black (GND)