background image

Checkpoint Systems, Inc.

  –  Field Service Installation Document  –  CKP P/N 

#######

Page 8 of 9

3.  From this pedestal’s reader, connect 

from the Interped OUT Port using an  
interpedestal network cable (shielded 
Cat 5e from RFID installation/cable 
kit (cable is CKP P/N 7206088 - and 
the kit is CKP P/N 10083615). Apply 
a 10cm ferrite core with 2 turns.

4.  Route Cat5 and coax cables to next 

pedestal (if not already). For either 
PP or PN type units, this connection 
will carries RFID lights and sound, 
as well as RFID Network signal.

 Figure 9: 

InterPED wiring

5.  Connect at the InterPED IN Port and apply a 10cm ferrite core with 2 turns. 
6.  At last pedestal, connect from NETWORK Port to the Evolve board for TCP/IP 

network sharing. 

7.  Connect the RF-EAS Sync cable (shown with ferrite core already applied). Apply 

10cm ferrite core.

8.  Connect the RFID Coax cable pair (this can be done at any time, before power up).

• RX4 to RX4 array keeping the labels accurate for future reference.
• RX3  to  RX3. 

9.  Connect PSU to the system. First use Voltmeter to 

id - polarity of DC power cord. C to 
Pin1 of connector and - to Pin 3 as shown. Insert plug 
into power receptacle, then tighten the screws until 
secure. If needed, PSUs can be “daisy-chained.”

Complete RFID Alarm LED Wiring

Lamp 1, Lamp 2 and Lamp Center all share the same pinout. Any lights for RFID to be supported, terminate the 1 
pin connector and plug in at the side of Reader chassis.

Optional: External Sounder Connection

Another sounder (besides the one inside the RFID reader) can be equipped. Install the unit inside the pedestal as 
recommended, then wire with same pin-out above. 

Pin #

2-Pin Euro Connector 

Wire Color (Polarity)

1

Right

Red    (+)

2

Left

Black (GND)

Содержание E10 2.0

Страница 1: ...CKP P N 10062884 E10 2 0 Quick Start Guide Dual RF RFID Pedestals Reference During Installation ...

Страница 2: ...PLUS are registered trademarks of Checkpoint Systems Inc All other product or service names are the property of their respective owners Information in this document is subject to change without notice Companies names and data used in examples herein are fictitious unless otherwise noted No part of the contents of this document may be reproduced or transmitted in any form or by any means without th...

Страница 3: ...s such as P P or A P type units are optional per site layout see Supported Configurations A P Type antenna EU and FCC version are available For ordering info see Region Specific Part Numbers in manual P P Type antenna also regional 1 RFID Install Kits w 2x Coax Adapters M to M L Shaped to alter wiring for Modified AP layouts AA where existing cable meets reader ANYTHING ELSE Tools Required Hammer ...

Страница 4: ...in at the connector labeled 2 above For other aisle configurations refer to Installation Manual or procedures below 1 RFID Coax Connector Side top 2 Side Panel with 4 Pin Digital Input Serial Port via RJ 45 and LTS SND covered in the GPIO section 3 Ethernet Port see Client Network connection 4 IN Interped communication 5 OUT Interped communication 6 12V DC Power Input conn Standard Single Aisle UH...

Страница 5: ... AN to RX6 of AP Figure 2 Standard Dual Aisle NA PA PN or NP AP AN 4 Use interpedestal coax cable to connect RX3 of AP to RX5 of PN 5 Use interpedestal coax cable to connect RX4 of AP to RX6 of PN 6 Use interpedestal network cable to connect Interpedestal OUT of AN to Interpedestal IN of AP 7 Use interpedestal network cable to connect Interpedestal OUT of AP to Interpedestal IN of PN 8 Connect 12 ...

Страница 6: ...quired There is a disatvantage to this where any shutdown to board functionality will disable MV to all subsequent pedestals this is a customer education opportunity basically their decision to make during planning Dual Aisle Configurations 2 1 One Reader Two Aisles 1R2A 2 1 1 One Reader for One and Half Aisle 1 5 Aisles Figure 4 AP Pedestal configured for 1 5 Aisles of RFID detection The Half Ais...

Страница 7: ...s configured for 2 Full and 2 half aisles In this pedestal layout the AP pedestals are in positions 1 and 3 see above Each system has both front and rear RFID Arrays driven by its own internal WRTZ 2000 Reader meanwhile in the center aisle position 2 a Passive Passive unit is installed which must have each array connected to the neighboring active Half aisles are outside the aisle which makes this...

Страница 8: ... RX3 of second AA to RX9 of PP 6 Use interpedestal coax cable to connect RX4 of second AA to RX10 of PP 7 Use interpedestal coax cable to connect RX7 of second AA to RX5 of second PN 8 Use interpedestal coax cable to connect RX8 of second AA to RX6 of second PN 9 Use interpedestal network cable to connect Interpedestal OUT of first PN to Interpedestal IN of first AA 10 Use interpedestal network ca...

Страница 9: ...ables 1 RFID Interpedestal Communication cable LED COMMs 1 RF EAS Coax Cable 1 RF EAS Sync Cable Figure 8 Single Aisle floor plan Note The number will vary in other aisles where the 8C modular cable will link between primaries for example Note RF EAS may use the same network refer to Step 6 below depending on if Evolve will have its own Ethernet uplink 2 Route Cat 5e from client network connection...

Страница 10: ...shown with ferrite core already applied Apply 10cm ferrite core 8 Connect the RFID Coax cable pair this can be done at any time before power up RX4 to RX4 array keeping the labels accurate for future reference RX3 to RX3 9 Connect PSU to the system First use Voltmeter to identify polarity of DC power cord Connect to Pin1 of connector and to Pin 3 as shown Insert plug into power receptacle then tig...

Страница 11: ...tool see Required tools An overview is provided below Launch DMS Tune system for RF EAS connect to Evolve Board Confirm default profile for RFID Reader s Apply Region and if applicable set the Application Mode to Dual Aisle Perform RX Map and EPC Positioning setup for Left and Right aisles Proceed with DMS to confirm detection ...

Страница 12: ...t increases in alarm activity Where applicable Checkpoint Systems Inc Electronic Article Surveillance EAS products comply with the Maximum Permissible Exposure limits FCC 47 C F R 1 1307 b 1 for US and RF Exposure limit RSS 102 table 4 2 for Canada Industry Canada Regulatory Compliance Statement This device complies with the Industry Canada license exempt RSS standard s Operation is subject to the...

Страница 13: ...t interference will not occur in a particular installation If this equipment experiences frequent interference from external sources or does cause harmful interference to radio communications reception which can be determined by turning the equipment off and on please contact a Checkpoint Systems representative for further assistance Where applicable Checkpoint Systems Inc Electronic Article Surve...

Страница 14: ...products on the European market The aim of the REACH regulation is to ensure a high level of protection of human health and the environment from chemical substances Checkpoint Systems substances management system follows and complies with the current revision of the REACH Regulation on the substances as identified by ECHA European Chemical Agency Checkpoint Systems products are considered articles...

Отзывы: