Testing Procedures
Omni Verifier
On the side of the Omni Verifier unit slide the toggle switch to “DV.” Depress the red button. The amber and
green lights will illuminate. If the green light is blinking, this indicates that the battery is low and the unit
needs to be placed onto the charging cradle.
Hold the Omni Verifier device approximately 24 inches above the deactivation pad and slowly lower until the
red indicator illuminates and the sounder beeps. This indicates that the deactivation field is present.
If you experience deactivation problems when testing your deactivators using either the DV1000 or Omni
devices, please check the following before placing a service call:
1. Locate the deactivation electronics box and confirm
it’s plugged in and/or the power switch is turned on.
A green light should be illuminated on the front of
the electronics box to indicate power.
2. If the light is on, the power supply is plugged in and
there is still no deactivation field present, confirm
the antenna cable and connector are plugged into
the back of the electronic housing.
3. If the problems persist, contact Checkpoint’s Service
Department (800
‐
253
‐
7580) to place a service call.
When placing a service call, please give a brief
description of the problem you are experiencing.