Using the First Time Configuration Wizard
Quantum Spark 1530 / 1550 Appliance R80.20.XX Getting Started Guide | 30
The
Software Blades Activation
page opens.
Security Management Server Authentication
For Centrally Managed appliances only:
When you select central management as your security policy management method, the
Security
Management Server Authentication
page opens.
Select an option to authenticate trusted communication with the Security Management Server:
n
Initiate trusted communication securely by using a one-time password
- The one-time
password is used to authenticate communication between the appliance and the Security
Management Server securely.
Enter a
one-time password
and confirm it. This password is only used for establishing the initial
trust. When established, trust is based on security certificates.
Important
- This password must be identical for the Secure Communication
authentication one-time password configured for the appliance object in the
SmartConsole of the Security Management Server.
n
Initiate trusted communication without authentication (not secure)
- Use this option only if there is
no risk of malicious behavior (for example, when in a lab setting).
n
Configure one-time password later
- Set the one-time password at a different time using the
WebUI application.
Software Blade Activation
Select the Software Blades to activate on this appliance.
QoS (bandwidth control) can only be activated from the WebUI after completing the First Time
Configuration Wizard.