Replacing Power Supply Units
Quantum Maestro Getting Started Guide | 50
Replacing Power Supply Units
Quantum Maestro Orchestrators are equipped with two replaceable Power Supply Units (PSUs). The PSUs
in these systems can work in a redundant configuration. It is possible to remove one of the PSUs without the
need to bring down the Quantum Maestro Orchestrator.
Important - PSUs have directional air flows similar to the fan module. The fan module
airflow must coincide with the airflow of all of the PSUs. If the PSU airflow direction is
different from the fan module airflow direction, it affects the Quantum Maestro
Orchestrator's internal temperature.
See:
n
"Airflow in MHO-175" on page 54
n
"Airflow in MHO-170 and MHO-140" on page 69
Removing a Power Supply Unit
Important:
n
Before you remove one of the PSUs, make sure that:
1. The
System Status LED
is lit in steady green (see
).
2. The
Power Supply Unit Status LEDs
on the PSU that you leave in the
Orchestrator are lit in steady green (see
).
n
To ensure proper cooling, do not leave the PSU slots of a Quantum Maestro
Orchestrator empty for more than five minutes.
To remove a PSU:
Step
Instructions
1
Disconnect the power cord from the PSU.
2
Grasp and hold the PSU handle with your hand.
3
Push the latch release with your thumb.
4
Pull out the PSU from the Quantum Maestro Orchestrator.
As you pull out the PSU, its status LEDs turn off.